246824-YTG-G-1208

Electric Heat Multipliers

 

Voltage

kW Capacity Multipliers1

Nominal

 

Applied

 

 

240

 

208

0.75

 

230

0.92

 

 

480

 

460

0.92

600

 

575

0.92

1.Electric heaters are rated at nominal voltage. Use this table to determine the electric heat capacity for heaters applied at lower voltages.

Sound Performance

Indoor Sound Power Levels

Size

 

 

ESP

Blower

 

 

Sound Power, dB (10-12) Watts

 

 

Model

CFM

Sound Rating1

 

Octave Band Centerline Frequency (Hz)

 

(Tons)

(IWG)

 

 

 

 

 

 

RPM

BHP

dB (A)

63

125

250

500

1000

2000

4000

8000

 

 

 

 

078

ZH/ZR/XP

2600

0.6

812

1.14

74

71

73

73

71

69

65

65

60

(6.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

090

ZH/ZR/XP

3000

0.6

854

1.47

77

74

76

76

74

72

68

68

63

(7.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

102

ZH/ZR/XP

3400

0.6

872

1.65

80

77

79

79

77

75

71

71

66

(8.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120

ZH/ZR/XP

4000

0.6

959

2.29

83

80

82

82

80

78

74

74

69

(10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

150

ZH/ZR/XP

5000

0.6

1132

3.74

87

84

86

86

84

82

78

78

73

(12.5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.These values have been accessed using a model of sound propagation from a point source into the hemispheric/free field. The dBA values provided are to be used for reference only. Calculation of dBA values cover matters of system design and the fan manufacture has no way of knowing the details of each system. This constitutes an exception to any specification or guarantee requiring a dBA value of sound data in any other form than sound power level ratings.

Outdoor Sound Power Levels

ZH/ZR/XP078-150

Size

Model

Sound Rating1

 

Octave Band Centerline Frequency (Hz)

 

(Tons)

dB (A)

125

250

500

1000

2000

4000

8000

 

078

ZH

83

88.0

82.5

81.5

78.0

73.0

69.0

62.0

(6.5)

 

 

 

 

 

 

 

 

 

090

ZH

83

89.5

83.5

82.0

78.0

72.5

68.0

60.5

(7.5)

 

 

 

 

 

 

 

 

 

102

ZH

90

93.5

92.5

88.0

84.5

79.0

74.5

68.0

(8.5)

 

 

 

 

 

 

 

 

 

120

ZH

90

94.0

92.0

88.5

84.5

80.0

75.5

68.5

(10)

 

 

 

 

 

 

 

 

 

150

ZH

84

90.0

84.5

81.5

77.5

72.0

68.5

61.5

(12.5)

 

 

 

 

 

 

 

 

 

078

ZR/XP

83

88.0

82.5

81.5

78.0

73.0

69.0

62.0

(6.5)

 

 

 

 

 

 

 

 

 

090

ZR/XP

83

89.5

83.5

82.0

78.0

72.5

68.0

60.5

(7.5)

 

 

 

 

 

 

 

 

 

102

ZR/XP

83

89.0

84.5

81.5

78.0

72.5

68.5

70.5

(8.5)

 

 

 

 

 

 

 

 

 

120

ZR/XP

83

89.5

83.5

81.0

78.0

72.0

68.5

70.5

(10)

 

 

 

 

 

 

 

 

 

150

ZR/XP

84

90.0

84.5

81.5

77.5

72.0

68.5

61.5

(12.5)

 

 

 

 

 

 

 

 

 

1. Rated in accordance with ARI 270 standard.

Johnson Controls Unitary Products

81

Page 81
Image 81
York R-410A manual Sound Performance, Electric Heat Multipliers, Indoor Sound Power Levels

R-410A specifications

York R-410A is a widely recognized and highly efficient refrigerant used in modern air conditioning systems. Developed as an environmentally friendly alternative to R-22, R-410A has gained popularity in the HVAC industry due to its numerous advantageous features and characteristics.

One of the main features of York R-410A is its ability to provide superior cooling performance. This refrigerant operates efficiently at both high and low temperatures, allowing systems using it to maintain optimal indoor climates even during extreme weather conditions. Its high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER) ratings make it a preferred choice for energy-conscious consumers, resulting in lower energy bills and a reduced carbon footprint.

Technologically, York R-410A systems feature advanced compressor designs that enhance their overall reliability and performance. These compressors are often equipped with variable-speed technology, enabling them to adjust their output to match the cooling demands of the space. This not only improves comfort levels but also leads to efficient energy consumption, reducing wear and tear on the equipment over time.

Another significant characteristic of York R-410A is its non-ozone-depleting properties. Unlike its predecessor R-22, which is being phased out due to its damaging effects on the ozone layer, R-410A is designed to minimize environmental impact. Its lower global warming potential (GWP) further underscores its role in promoting sustainability within the HVAC sector.

Furthermore, York R-410A systems are engineered with enhanced safety features. The refrigerant is non-toxic and non-flammable, which makes it safer for use in both residential and commercial applications. Additionally, its high thermal stability reduces the risk of breakdown or leakage, contributing to longer system lifespans and lower maintenance costs.

In conclusion, York R-410A stands out as a cutting-edge refrigerant that combines efficiency, safety, and environmental responsibility. With its advanced technologies and remarkable characteristics, it meets the demands of modern air conditioning requirements while paving the way for a sustainable future in HVAC systems. Adopting York R-410A not only benefits individual users through improved comfort and lower energy bills but also plays a vital role in protecting our planet's ozone layer and mitigating climate change.