York R-410A XP078-150Side Duct Application, XP078 6.5 Ton Side Duct, XP090 7.5 Ton Side Duct

Models: R-410A

1 128
Download 128 pages 30.42 Kb
Page 72
Image 72
XP078-150 Side Duct Application

246824-YTG-G-1208

XP078-150 Side Duct Application

XP078 (6.5 Ton) Side Duct

Air Flow

 

 

 

 

 

 

Available External Static Pressure - IWG1

 

 

 

 

 

 

 

0.2

0.4

 

0.6

 

0.8

1.0

1.2

1.4

 

1.6

 

1.8

2.0

(CFM)

 

 

 

 

RPM BHP

RPM BHP

RPM BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM BHP

RPM BHP

RPM

BHP

RPM

BHP

 

 

 

1.5 HP

& Field Supplied

Drive

 

 

 

Standard 1.5

HP & Drive

 

 

 

Hi

Static 2 HP & Drive

 

1800

754

0.24

814

0.44

872

0.63

929

0.79

985

0.93

1039

1.07

1094

1.20

1150

1.33

1207

1.45

1266

1.59

2000

779

0.37

840

0.58

898

0.76

955

0.92

1010

1.07

1065

1.21

1120

1.34

1176

1.46

1233

1.59

1292

1.72

2200

809

0.52

870

0.73

928

0.91

985

1.07

1040

1.22

1095

1.36

1150

1.48

1206

1.61

1263

1.74

1321

1.87

2400

842

0.69

903

0.90

961

1.08

1018

1.24

1073

1.39

1128

1.52

1183

1.65

1239

1.78

1296

1.91

1355

2.04

2600

879

0.87

939

1.08

998

1.26

1054

1.42

1110

1.57

1165

1.71

1220

1.84

1275

1.96

1332

2.09

1391

2.22

2800

918

1.08

979

1.28

1037

1.46

1093

1.63

1149

1.77

1204

1.91

1259

2.04

1315

2.16

1371

2.29

-

-

3000

960

1.30

1020

1.50

1079

1.68

1135

1.85

1191

1.99

1246

2.13

1301

2.26

-

-

-

-

-

-

3200

1004

1.54

1065

1.74

1123

1.92

1179

2.09

1235

2.23

-

-

-

-

-

-

-

-

-

-

3400

1050

1.79

1111

2.00

1169

2.18

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 HP & Field Supplied Drive

 

1.Blower performance includes 2” filters. See STATIC RESISTANCE table for additional applications.

2.See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.

3.kW = BHP x 0.932.

XP090 (7.5 Ton) Side Duct

Air Flow

 

 

 

 

 

 

Available External Static Pressure - IWG1

 

 

 

 

 

 

 

0.2

0.4

0.6

0.8

1.0

1.2

 

1.4

1.6

 

1.8

 

2.0

 

(CFM)

 

 

 

 

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

RPM BHP

 

 

1.5 HP & Field

Supplied Drive

 

 

 

Standard 1.5 HP & Drive

 

 

 

 

Hi Static 3 HP & Drive

 

2000

779

0.37

840

0.58

898

0.76

955

0.92

1010

1.07

1065

1.21

1120

1.34

1176

1.46

1233

1.59

1292

1.72

2200

809

0.52

870

0.73

928

0.91

985

1.07

1040

1.22

1095

1.36

1150

1.48

1206

1.61

1263

1.74

1321

1.87

2400

842

0.69

903

0.90

961

1.08

1018

1.24

1073

1.39

1128

1.52

1183

1.65

1239

1.78

1296

1.91

1355

2.04

2600

879

0.87

939

1.08

998

1.26

1054

1.42

1110

1.57

1165

1.71

1220

1.84

1275

1.96

1332

2.09

1391

2.22

2800

918

1.08

979

1.28

1037

1.46

1093

1.63

1149

1.77

1204

1.91

1259

2.04

1315

2.16

1371

2.29

1430

2.43

3000

960

1.30

1020

1.50

1079

1.68

1135

1.85

1191

1.99

1246

2.13

1301

2.26

1356

2.39

1413

2.51

1472

2.65

3200

1004

1.54

1065

1.74

1123

1.92

1179

2.09

1235

2.23

1290

2.37

1345

2.50

1400

2.62

1457

2.75

1516

2.89

3400

1050

1.79

1111

2.00

1169

2.18

1226

2.34

1281

2.49

1336

2.63

1391

2.75

1447

2.88

1504

3.01

1562

3.14

3600

1099

2.07

1159

2.27

1218

2.45

1274

2.62

1330

2.76

1385

2.90

1440

3.03

1495

3.15

1552

3.28

1611

3.42

3800

1149

2.36

1209

2.56

1268

2.74

1324

2.91

1380

3.05

1435

3.19

1490

3.32

1545

3.44

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 HP & Field Supplied Drive

 

 

 

1.Blower performance includes 2” filters. See STATIC RESISTANCE table for additional applications.

2.See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.

3.kW = BHP x 0.932.

XP102 (8.5 Ton) Side Duct

Air Flow

 

 

 

 

 

 

Available External Static Pressure - IWG1

 

 

 

 

 

 

 

0.2

0.4

0.6

0.8

 

1.0

1.2

1.4

 

1.6

 

1.8

2.0

(CFM)

 

 

 

RPM

BHP

RPM

BHP

RPM

BHP

RPM BHP

RPM

BHP

RPM

BHP

RPM BHP

RPM BHP

RPM

BHP

RPM

BHP

 

 

2 HP & Field

Supplied Drive

 

 

 

Standard 2 HP & Drive

 

 

 

 

Hi Static 3 HP & Drive

 

2200

632

0.23

684

0.44

734

0.65

783

0.84

830

1.03

876

1.21

921

1.39

966

1.56

1009

1.74

1051

1.91

2400

639

0.32

691

0.53

741

0.74

790

0.93

837

1.12

883

1.30

928

1.48

972

1.65

1015

1.83

1058

2.00

2600

646

0.41

698

0.62

748

0.82

797

1.02

844

1.21

890

1.39

936

1.57

980

1.74

1023

1.92

1065

2.09

2800

654

0.50

706

0.71

756

0.92

805

1.11

852

1.30

898

1.48

943

1.66

987

1.83

1031

2.01

1073

2.18

3000

663

0.60

714

0.81

765

1.02

813

1.21

861

1.40

907

1.58

952

1.76

996

1.93

1039

2.11

1082

2.28

3200

673

0.71

724

0.93

774

1.13

823

1.32

871

1.51

917

1.69

962

1.87

1006

2.05

1049

2.22

1091

2.39

3400

684

0.84

735

1.05

785

1.25

834

1.45

882

1.63

928

1.82

973

2.00

1017

2.17

1060

2.34

1102

2.52

3600

696

0.98

747

1.19

798

1.39

846

1.59

894

1.78

940

1.96

985

2.14

1029

2.31

1072

2.48

1115

2.66

3800

709

1.14

761

1.35

811

1.55

860

1.75

907

1.93

953

2.12

999

2.29

1043

2.47

1086

2.64

1128

2.81

4000

724

1.31

776

1.52

826

1.72

874

1.92

922

2.11

968

2.29

1013

2.47

1057

2.64

1100

2.82

1143

2.99

4200

740

1.50

792

1.71

842

1.92

890

2.11

938

2.30

984

2.48

1029

2.66

1073

2.83

1116

3.01

1159

3.18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 HP & Field Supplied Drive

1.Blower performance includes 2” filters. See STATIC RESISTANCE table for additional applications.

2.See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.

3.kW = BHP x 0.932.

72

Johnson Controls Unitary Products

Page 72
Image 72