York YR manual Accessories and Modifications

Models: YR

1 40
Download 40 pages 10.54 Kb
Page 17
Image 17

Accessories and Modifications

FORM 160.81-EG1

SOLID STATE STARTER

The Solid State Starter is a reduced voltage starter that controls and maintains a constant current flow to the motor during startup. It is compact and mounted on the chiller at the motor terminals. Power and control wiring is factory supplied. Available for 200-600 volts, the starter enclosure is NEMA-1 with a hinged access door with lock and key. Electrical lugs for incoming power wiring are provided.

Standard features include: digital readout at the OptiV- iew Control Center of the following:

Display Only:

3-phase voltage A, B, C

3-phase current A, B, C

Input power (kW)

kW Hours

Starter Model

Motor Run (LED)

Motor Current % Full-load Amps

Current Limit Setpoints

Pulldown Demand Time Left

Programmable:

Local Motor Current Limit

Pulldown Demand Limit

Pulldown Demand Time

Other features include: low line voltage; 115-volt con- trol transformer; three-leg sensing overloads; phase ro- tation and single-phase failure protection; high tempera- ture safety protection; motor current imbalance and undervoltage safeties; open and close SCR protection; momentary power interruption protection. The LCSSS is cooled by a closed-loop, fresh water circuit consist- ing of a water-to-water heat exchanger and 1/25 HP circulating pump. All interconnecting water piping is factory installed and rated for 150 PSIG working pres- sure. Optional unit-mounted circuit breaker includes ground fault protection and provides 65,000 amp short- circuit withstand rating in accordance with UL Standard

508.A non-fused disconnect switch is also available. Both options are padlockable.

BAS REMOTE CONTROL

A communication interface permitting complete ex- change of chiller data with any BAS system is available with optional ISN translator. ISN translator also allows BAS system to issue commands to the chiller to control its operation. ISN translators come in two models, con- trolling up to four chillers and eight chillers respectively.

FACTORY INSULATION OF EVAPORATOR

Factory-applied thermal insulation of the flexible, closed- cell plastic type, 3/4" (19mm) thick is attached with va- por-proof cement to the evaporator shell, flow cham- ber, evaporator tube sheets, suction connection, and (as necessary) to the auxiliary tubing. Not included is the insulation of water boxes and nozzles. This insula- tion will normally prevent condensation in environments with relative humidities up to 75% and dry bulb tem- peratures ranging from 50° to 90°F (10° to 32°C). 1-1/ 2" (38mm) thick insulation is also available for relative humidities up to 90% and dry bulb temperatures rang- ing from 50° to 90°F (10° to 32°C).

WATER FLANGES

Four 150 Ib. ANSI raised-face flanges, for condenser and evaporator water connections, are factory welded to water nozzles. Companion flanges, bolts, nuts and gaskets are not included.

SPRING ISOLATION MOUNTING

Spring Isolation mounting is available instead of stan- dard isolation mounting pads when desired. Four level- adjusting/spring-type vibration isolator assemblies with non-skid pads are provided with mounting brackets for field installation. Isolators are designed for one-inch (25.4 mm) deflection.

WATER FLOW SWITCHES

Paddle-type, vapor-proof water flow switches suitable for 150 psig (1034 kPa) DWP for chilled and condenser water circuits. Switch for 115V-1-50/60 Hz service. A chilled water flow switch is required. Condenser water flow switch is optional.

SEQUENCE CONTROL KIT

For two, three or four units with chilled water circuits connected in series or parallel, the kit consists of return water thermostat, lead-lag selector switch for sequence starting, and time delay relay, with NEMA-1 enclosures, designed for 115V-1-50/60 Hz.

STARTER – FIELD INSTALLED

A field installed, electro-mechanical compressor motor starter is available, selected for proper size and type for job requirements and in accordance with YORK En- gineering Standard R-1131 for Starters.

YORK INTERNATIONAL

17

Page 17
Image 17
York YR manual Accessories and Modifications