Zanussi ZCM 5600 manual Z C M, Pressure Testing, Checking The Grill, Checking The Hotplate

Models: ZCM 5600

1 52
Download 52 pages 23.88 Kb
Page 49
Image 49
6. PRESSURE TESTING

Z C M 5 6 0 0

If the wiring is extended or a completely new cable fitted a

3-pin 13 amp plug should be fitted. (See Fig.4a). Connect the

GREEN AND

YELLOW

wires as follows:

 

 

 

BROWN to the Live Terminal.

 

BLUE to the Neutral Terminal.

 

GREEN and YELLOW to the Earth Terminal.

13 AMP

As the colours of the wires in the mains lead which you fit

 

may not correspond with the coloured markings identifying

 

the terminals in your plug, proceed as follows:

 

The wire which is GREEN and YELLOW must be connected

 

to the terminal in the plug which is marked with the letter 'E'

 

or by the earth symbol

or coloured GREEN or GREEN

 

and YELLOW.

 

 

The wire which is coloured BLUE must be connected to the

BLUE

BROWN

terminal which is marked with the letter 'N' or coloured

Fig.4a

BLACK.

 

The wire which is coloured BROWN must be connected to the terminal which is marked with the letter 'L' or coloured RED.

FIT A 13 AMP FUSE TO THE PLUG HOLDER.

Ensure that the supply cable cannot get caught by the stability bracket. Plug in the appliance.

6. PRESSURE TESTING

1The hotplate rapid burner injector is used as a pressure test point.

2Lift the lid and connect the pressure gauge to the rapid burner injector.

3Check the supply pressure by turning rapid burner tap on full and one other hotplate tap full on and light the appropriate burner. The pressure should be 20mbar for natural gas.

4.Turn off the taps and disconnect the pressure gauge.

7. CHECKING THE GRILL

Place the grill pan containing the grid and with handle attached into the grill compartment. To light the grill burner, turn the grill tap to its full on position, then press the ignition button until the burner is lit.

8. CHECKING THE HOTPLATE

Lift the lid. Fit the burner crowns and caps ensuring that they are correctly seated. Fit the pan supports. Check each of the hotplate burners in turn by turning the hotplate tap to it's full on position then pressing the ignition button until the burners are lit.

9. CHECKING LID SHUT-OFF DEVICE

1.Lift the lid.

2.Turn one hotplate burner tap to its full on position, then push and release the ignition button.

3.Close lid. There should now be no gas supply to the hotplate and the burner will go out.

4.Turn off the hotplate tap and lift the lid. The gas supply should now be restored to the hotplate, when the tap is turned on.

49

Page 49
Image 49
Zanussi ZCM 5600 manual Z C M, Pressure Testing, Checking The Grill, Checking The Hotplate, Checking Lid Shut-Off Device