UM Command - Codepage & Memory Inquiry

Description This command will cause the printer to send to the host of the currently selected codepage and memory status through the RS-232 port.

This command also disables software flow con- trol (XON/XOFF). Hardware flow control is not disabled (DTR/CTS). To restart software flow control a reset (^@ command) or power must be recycled.

Syntax UM

The printer will send information about the cur- rently selected code page and memory status back to the host in the following format:.

UMp1,p2,p3,p4,p5,p6,p7,p8

p1 = Image buffer size in KBytes.

p2 = Form memory allocation size in KBytes. p3 = From memory free in KBytes.

p4 = Graphic memory allocation size in KBytes.

p5 = Graphic memory free in KBytes.

p6 = External font memory allocation size in KBytes.

p7 = External font memory free in KBytes.

p8 = Appends a response in the UI com- mand data format. See UI command on page 3-96.

Example: UM￿

See Also: I, M, U, UI and UP commands.

980352-001 Rev.A