VCommand - Define Variable

Description Use this command to define variable data for the text and bar code data fields in stored forms. Variable data can be combined with fixed data or other data types (counter, date, etc..) in text or bar code data fields.

Syntax Vp1,p2,p3,"[-]PROMPT"

Parameters p1 = Variable number. Range: 00 to 99 .

Variable (reference) numbers are se- quential and must be input into a form in ascending order.

p2

= Maximum number of characters

 

Range: 1 to 99 .

 

 

This is the maximum number of charac-

 

ters allowed in the variable field.

p3

= Field Justification.

 

L = Left

R = Right

C = Center N = No Justification Note: Right and center justification does not apply to soft fonts.

“PROMPT” = An ASCII text field that will be transmitted to the host (via the serial in- terface) each time this command is exe- cuted. Use the prompt to ask for a value to be entered for the variable.

KDU Options [-] = Having the first character of the prompt a single minus sign will cause the prompt to display only once after form retrieval.

KDU Character The KDU allows a maximum of 40 characters Number Limit for entry into a variable data field and display.

KDU Range (p2 ): 1 to 40, but not to exceed a total of 1500 bytes for all variables.

980352-001 Rev.A