AUTOFR - Automatic Form Printing Feature

AUTOFR treats any incoming data as a variable in- tended for printing. This means if you send the printer a memory partition command, the label will print, if you send a delete command - the label will print! So, while you are testing AUTOFR it is best to use another name for the form. Once you are satis- fied with the form, rename it AUTOFR before you download it. There is no need to specify a file exten- sion.

Isolating Data From Place the printer in the diagnostic dump mode the Input Device and send from your data input device. All charac-

ters the device sends will be printed on the label.

·If nothing prints, nothing is arriving - check pin-outs and serial settings.

Disabling AUTOFR Send a XOFF data character (13 hex. or ASCII

19)or a NUL (00 hex. or ASCII 0) to the printer. The form may now be deleted from the printer.

Removing AUTOFR The programmer must send a Delete Form - FK command to the printer after disabling

AUTOFR.

Example: FK"AUTOFR"￿