Zebra Technologies EPL2 manual MaxiCode Data Formatting, Syntax bp1,p2,M,p4 AIM MaxiCode Data

Models: EPL2

1 138
Download 138 pages 45.57 Kb
Page 37
Image 37

Using AIM Specified

MaxiCode Data

Formatting

The EPL printer can use and automatically de- code the AIM ITS (International Technical Stan- dards) MaxiCode data format. The printer detects the message/start header ([)>RS), field separator (GS), and the end of message marker (RS EOT) data control strings.

The hexadecimal (ASCII) data control strings are in the following table. See the EPL2 dump mode character map in Appendix A.

Control String

Hexadecimal Code

Message/Start Header

[ ) > RS

5B 29 3E 1E

Field Separator

 

GS

1D

End Of Message Marker

RS EOT

1E 04

 

 

Syntax bp1,p2,M,p4 “[AIM MaxiCode Data]”

Example b20,400,M,m2”001,840,93065,1692,[)>RS

01GS98XXXZZFDAAFGSSHIPGS309GSGS1/1GS10GS

NGSGSCAMARILLOGSCAGSRSEOT!!!!!!!!!!!!!!!!!!!!!!!”

￿

Notes:

1)This programming example represents actual data used to format a single AIM compliant MaxiCode symbol as pro- grammed by a major international and domestic shipping com- pany.

2)The shipper has explicitly set the MaxiCode symbol for Mode

2. This can be omitted by the programmer and the printer will auto-select the mode per the rules on page 3-16.

3)The shipper has used the "!" character to pad the symbol's data. A scanner reads back all the "Data" within the quotation marks, including the "!" characters following the End Of Mes- sage Marker (EOT).

4)All of the data fields in the Low Priority Message are not used in the example. Some are left empty with the field delim- iting GS character used as a format field holder.

980352-001 Rev.A

3-19

Page 37
Image 37
Zebra Technologies EPL2 manual MaxiCode Data Formatting, Syntax bp1,p2,M,p4 AIM MaxiCode Data