oB Command - Cancel Auto Bar Code Optimization

Description: This command allows the advanced program- mer to disable bar code optimization for rotated (90° & 270°) bar codes.

Syntax: oB

Parameters: None

The oB command is a global printer com- mand.

It can not be issued inside of a form.

It must be issued prior to issuing a bar code command (and printing).

To reapply bar code defaults, issue a o (small letter “o”) command. See page C-63for impor- tant details on the effects of using the o com- mand.

Reset the printer with a ^@ command with flash firmware printers or cycle printer power to clear the oB command and return the printer to normal operation.

Zebra Technologies Corporation does not warrant, support, or endorse the use of bar codes generated by the printer after a oB command has been issued.

Zebra Technologies Corporation does not support this feature other than with the information supplied in this document.