YCommand - Serial Port Setup

Description Use this command to establish the serial port communication parameters.

Syntax Yp1,p2,p3,p4

Parameters p1 = Baud rate

 

 

p1

 

Description

 

 

 

38

 

38,400 baud (38K)

 

 

 

19

 

19,200 baud

 

 

 

96

 

9,600 baud

 

 

 

48

 

4,800 baud

 

 

 

24

 

2,400 baud

 

 

 

12

 

1,200 baud

 

 

 

 

 

 

 

p2

= Parity.

 

 

 

 

Values: O = Odd parity

 

 

 

 

E = Even parity

 

 

 

 

N = No parity

p3

= # Data bits.

 

 

Values: 7 = Seven data bits

 

 

 

 

8 = Eight data bits

p4

= # Stop bits.

 

 

Values:

1 = One stop bit

2 = Two stop bits.

After receiving this command, the printer will automatically reset enabling the new rate.

To send commands and data to the printer, the host’s serial port parameters must match the printer’s serial port parameters. Verify the printer’s configuration set- tings with the AutoSense/Dump Mode Printout, see the printer’s user’s manual for details.

The printer’s default serial port parameters are:

9600 baud, No Parity, 8 Data Bits, 1 Stop Bit

Change the printer’s serial port parameters with the Y command after communication has been estab- lished with the host. The host parameters must then be changed to resume communication.

Example: Y19,O,7,1￿

:sets 19,200 baud, odd parity,

 

:7 data bits and 1 stop bit.

3-108

980352-001 Rev.A

Page 126
Image 126
Zebra Technologies EPL2 manual Command Serial Port Setup, Syntax Yp1,p2,p3,p4 Parameters p1 = Baud rate, Example Y19,O,7,1