Zebra Technologies EPL2 manual Command Bar Code, To Print

Models: EPL2

1 138
Download 138 pages 45.57 Kb
Page 29
Image 29

BCommand - Bar Code

Description Use this command to print standard bar codes. Syntax Bp1,p2,p3,p4,p5,p6,p7,p8,"DATA"

Parameters p1 = Horizontal start position (X) in dots p2 = Vertical start position (Y) in dots. p3 = Rotation

Value

Description

0No rotation

190 degrees

2180 degrees

3270 degrees

p4 = Bar Code selection (see Table 2-1 on next page).

p5 = Narrow bar width in dots. (see Table 2-1 on next page).

p6 = Wide bar width in dots. Acceptable values are 2-30.

p7 = Bar code height in dots.

p8 = Print human readable code. Values: B=yes or N=no.

DATA” = Represents a fixed data field. The data in this field must comply with the selected bar code’s specified format.

The backslash (\) character designates the fol- lowing character is a literal and will encode into the data field. Refer to the following examples:

To Print

Enter into data field

\”

“Company”

\”Company\”

\

\\

\code\

\\code\\

980352-001 Rev.A

3-11

Page 29
Image 29
Zebra Technologies EPL2 manual Command Bar Code, To Print