UP Command - Codepage & Memory Inquiry/Print

Description This command will cause the printer to print and send the currently selected codepage and memory status to the host through the RS-232 port.

This command also disables software flow con- trol (XON/XOFF). Hardware flow control is not disabled (DTR/CTS). To restart software flow control a reset (^@ command) or power must be recycled.

Syntax UP

The printer will send information about the cur- rently selected code page and memory status back to the host followed by printing the current printer configuration. For an example of the configuration printout, see the U command.

The format of data sent to the host is as follows:

UPp1,p2,p3,p4,p5,p6,p7,p8,p9

p1 = Image buffer size in KBytes.

p2 = Form memory allocation size in KBytes. p3 = From memory free in KBytes.

p4 = Graphic memory allocation size in KBytes.

p5 = Graphic memory free in KBytes.

p6 = External font memory allocation size in KBytes.

p7 = External font memory free in KBytes.

p8 = Appends a response in the UI com- mand data format. See UI command on page 3-96.

Example: UP￿

See Also I, M, U, UI and UM commands.