b Command - 2D Bar Code - PDF417 Specific Options

p9 (f) = Bar code origin point Values: 0 or 1, Default is 1

f1- Center of bar code as defined by the automatically adjusted symbol size, i.e. width and height. Parameters p4 and p5 values are maximum values only.

f0- Upper left corner of bar code.

p10 (x) - module width (in dots) Values: 2 - 9 (i.e. x2-x9)

Default: Auto selects 6 (dots). Tests data with maximum size limit set by p4 and p5 and then the other optional parame- ters. The printer automatically reduces the module width in one dot increments until the data fits within the symbols maximum dimensions (and other ap- plied parameters) or until 3 dots has failed, then reports an error.

p11 (y) - set bar height (in dots) Range: 4 - 99 (i.e. y4-y99) Default: 4 times module width (p10)

p12 (r) - maximum row count

Maximum limit for the number of rows to be used for auto selecting symbol features.

p13 (l) - maximum column count Maximum limit for the number of col- umns to be used for auto selecting sym- bol features.

p14 (t) - truncated flag - legal values are: 0 = not truncated, 1= truncated

See the PDF 417 specification for details.

p15 (o) - rotation

Values: 0= 0º, 1= 90º, 2= 180º, 3= 270º Settings of 90° & 270° will cause the sym- bols maximum height (p4) and width (p5) values to transpose when automatically cal- culating and generating the symbol, i.e. the height would affect column dimensions and width would affect row dimensions.

3-22

980352-001 Rev.A

Page 40
Image 40
Zebra Technologies EPL2 manual P9 f = Bar code origin point Values 0 or 1, Default is