Zebra Technologies EPL2 manual OM Command Disable Initial Esc Sequence Feed, Syntax oM

Models: EPL2

1 138
Download 138 pages 45.57 Kb
Page 86
Image 86

oM Command - Disable Initial Esc Sequence Feed

Description This command disables the automatic label cal- ibration routine executed by the printer upon receiving the first escape command sequence from the Windows printer driver. The printer normally measures a single label and sets the top of form prior to printing the first label after a power-up reset. The Windows™ printer driver issues escape sequences when printing.

This command’s primary use is to save preprinted forms such as serialized labels, tags or tickets.

Syntax oM

This command must be issued prior to printing with the Windows driver’s or any other Escape (esc) mode printing operation.

To reinitialize label calibration, issue a o (111 dec. or 6F hex.) command.

3-68

980352-001 Rev.A

Page 86
Image 86
Zebra Technologies EPL2 manual OM Command Disable Initial Esc Sequence Feed, Syntax oM