Zebra Technologies P520 user manual Troubleshooting, Solution

Models: P520

1 57
Download 57 pages 24 Kb
Page 42
Image 42
•Printing shows very pale or inconsistent results. Possible Cause

Printing shows very pale or inconsistent results. Possible Cause

A • Ribbon have been stored improperly or is damaged. B • Cards may not meet specifications.

C • Contrast and/or Intensity may be set to values which are too high.

D • Dust or embedded contamination on elements of the Print Head.

>>Solution

A1 • Change ribbon and print again.

B1 • Use a different supply of cards.

C1 • Adjust Contrast and/or Intensity values in software.

D1 • Perform a Cleaning of the Print Head (see 4 • 2 Cleaning the Print Head).

Printing shows blurry printed image. Possible Cause

A • Ribbon may not be correctly positioned.

B • Ribbon may not synchronized on the correct color panel position.

C • Cards may not meet specifications.

D • Dust inside the printer and/or dirty Cleaning Roller.

>>Solution

A1 • Open cover and press down the Print Head Unlock Lever to open the Print Head carriage. The Print Head will move up.

A2 • Check that the ribbon is properly rolled onto the ribbon cores.

A3 • Push down on the Print Head Lock Lever until an audible “click” signals the locked-down position.

A4 • Ribbon will automatically synchronize.

A5 • Print again.

B1 • Open cover and press down the Print Head Unlock Lever to open the Print Head carriage. The Print Head will move up.

B2 • Push down on the Print Head Lock Lever until an audible “click” signals the locked-down position.

B3 • Ribbon will automatically synchronize.

B4 •Print again.

C1 • Use a different supply of cards.

D1 • Perform a cleaning of the Print Head (See 4 • 2 Cleaning the Print Head). D2 • Replace Cleaning Roller (See 4 • 3 Cleaning Cartridge).

•Printing shows blurry printed image. Possible Cause36 TROUBLESHOOTING36Manual backgroundManual backgroundManual background TROUBLESHOOTING

Page 42
Image 42
Zebra Technologies P520 Troubleshooting, Solution, Printing shows very pale or inconsistent results. Possible Cause