Zebra Technologies TTP 2100 manual Calibrating the TOF Sensor

Models: TTP 2100

1 36
Download 36 pages 33.61 Kb
Page 17
Image 17

Installation

Top of Form (TOF) Sensor

Calibrating the TOF Sensor

1.Open the printhead.

2.Remove ticket stock.

3.Press and hold the Feed button, and then close the printhead (keeping the button pressed all the time).

4.Release the button.

The Status LED should be off.

5.Load ticket stock (slide it into the paper guide and let the printer auto load the paper).

Note • To ensure good calibration conditions, lightly press the ticket stock towards the bottom of the input guide during calibration.

The printer will forward the paper until it finds two TOF marks and then stop and save all TOF-mark parameters.

6.Open the printhead and remove the ticket stock.

7.Close the printhead and feed the tickets in through the paper guide again. The printer is ready for use.

Repeat this procedure if the calibration fails or if the printer is used with tickets that differ from the original specification.

Note • If you use the Dual guide 01990-400 on your printer, you must calibrate twice (once in the wide paper path and once in the narrow). The printer will choose the appropriate set of parameters based on which paper path contains ticket stock.

17

11/04/2009

TTP 2100 Operator Guide

P1021708-001

Page 17
Image 17
Zebra Technologies TTP 2100 manual Calibrating the TOF Sensor