Zebra Technologies TTP 2100 manual Electrostatic Discharges and Earth Currents, Ambient Light

Models: TTP 2100

1 36
Download 36 pages 33.61 Kb
Page 22
Image 22

22

Installation

Installation Considerations

Caution • NEVER use screws that go into the printer more than 4 mm! This will destroy the electronics inside.

Electrostatic Discharges and Earth Currents

Preventing ESD and earth currents from affecting the printer operation requires proper connection of the printer chassis to protective earth through a mounting platform or through a separate earth conductor. A threaded hole for an M4 earth screw is provided on the back of the printer. Use an M4 x 10 screw and two lock washers when fastening the ground cable.

Figure 8 • Location of Earth Grounding Screw

E a rth

S cre w

Note • An optional antistatic brush can be fitted to the front of the printer if required.

Ambient Light

There is an optical sensor at the paper exit at the front of the printer.

To ensure proper printer operation, design the kiosk so that it prevents direct sunlight or light from indoor lamps from reaching the sensor through the paper exit.

P1021708-001

TTP 2100 Operator Guide

11/04/2009

Page 22
Image 22