Polaris P1000i, P2000i manual General Specifications

Page 63

SPECIFICATIONS

General Specifications

 

ALTERNATOR

 

 

 

 

 

 

Model

P1000i

 

P2000i

 

 

 

 

Rated Frequency (Hz)

 

50

 

 

 

 

Rated Voltage (V)

 

240

 

 

 

Rated Current (A)

3.75

 

6.67

 

 

 

 

Max Current (A)

4.17

 

8.33

 

 

 

DC Output Voltage

12V (5A)

 

 

 

 

Rated Output

900 W

 

1600 W

 

 

 

 

Maximum Output

1000 W

 

2000 W

 

 

 

Phase

Single

 

 

 

 

 

ENGINE

 

 

 

 

 

 

Model

KG144

 

KG158

 

 

 

Type

Single cylinder, 4 stroke, vertical shaft, air-cooled, OHV

 

 

 

Displacement (cc)

58

 

106

 

 

 

Engine Oil

POLARIS 5W-30 Generator Oil

 

 

 

Engine Oil Capacity qt (L)

(0.25 or 0.26 L

 

.42(.4)

 

 

 

Intake Valve Clearance

0.18-0.10 mm (0.0031-0.0039 in.)

 

 

Exhaust Valve Clearance

0.10-0.15 mm (0.0039-0.0059 in.)

 

 

Spark Plug-Gap

UR5 - 0.6 - 0.7 mm (0.024 - 0.028 in.)

 

 

 

 

 

GENERAL

 

 

 

 

 

Fuel

91 Octane (Up to 10% Oxygenated)

 

 

 

 

Fuel Tank Capacity

2.6 L (0.7 gallons)

 

3.8 L (1 gallon)

 

 

 

Starting System

Recoil

 

 

 

 

Dimensions (L x W x H)

493 mm x 264 mm x 419 mm

 

545 mm × 330 mm × 448mm

(19.4 in. x 10.4 in. x 16.5 in.)

 

(21.4in. x 13 in. x 17.6 in.)

 

 

 

 

Weight

16.5 kg (36.4 lbs.)

 

24.18 kg (53.3 lbs.)

 

 

 

 

Full Tank Run Time

4 Hours

 

3.5 Hours

Hours at Rated Load

 

 

 

 

 

 

 

AC Circuit Breaker

Electronic

 

 

DC Fuse

5 Amp

 

 

DC Charging Cord

Standard

 

 

 

 

62

Image 63
Contents Polaris Power Table of Contents Welcome IntroductionIntended Use Safety Precautions Alcohol or Drug USE Signal Words and Safety TermsP1000iP2000i Identification Numbers and LocationsBefore and During Operation SafetySafety Warnings and Precautions GeneralFire Safety Operator Safety Fuel Safety Carbon Monoxide Safety Electrical Safety Equipment Modifications Extension Cord InformationHot Exhaust Caution Safety Labels and LocationsCarbon Monoxide Warning Outdoor Use only Danger LabelSafety Generator Components Controls and FeaturesP1000i P2000i Control Panel ComponentsStarter Recoil Grip Engine Fuel SwitchChoke Lever Fuel Tank Cap Vent LeverDC Receptacle and Fuse Smart Throttle SwitchIndicator Panel Ground TerminalAC Receptacles Parallel Receptacles Overload Protector Reset SwitchAdding Engine Oil First USE InstructionsFuel Recommendation Adding Fuel PRE-OPERATION Inspection Pre-Operation ChecklistRefueling Safe Operating PrecautionsOperation Fuel RecommendationsRemove the fuel tank cap a Starting the Engine Before Starting the EnginePosition the engine switch to on Stopping the Engine AC Operation AC Capacity Wattage Reference Table DC Operation Power ManagementOperation Smart Throttle System Disconnecting the Battery Charging CableConnections to a Building Electrical System Standby PowerParallel Generator Operation Parallel operation procedureShutting off the generators Carburetor Modification High Altitude UseEmission Control System Information Source of EmissionsAlterations Replacement Parts Problems Affecting EmissionsImportance of Maintenance MaintenanceSafety Precautions Maintenance SafetyPeriodic Maintenance Chart Periodic MaintenanceOpening the Service Door Fuel Line Inspection Initial MaintenanceFuel System Hour Initial Break-InOFF Engine Oil Oil RecommendationOil Level Inspection Oil Change Procedure Maintenance Air Filter Inspection Air FiltersAir Filter Replacement Air Filter CleaningSpark Plug Spark Plug Inspection and ReplacementGap should be 0.6 0.7 mm Transportation and Storage TransportationTransporting the Generator Storage Preparation StorageAccessing the Fuel Tank Draining Fuel from the Fuel Tank and Carburetor Fogging the Engine Removing from Storage Storage PrecautionsGeneral Specifications SpecificationsModified coefficient table of ambient condition power Polaris Lubricants and Maintenance ProductsP1000i Wiring Diagram Wiring DiagramsRed Gray Brown White Black P2000i Wiring DiagramEngine Turns Over, but Will Not Start TroubleshootingTroubleshooting Symptoms Engine Will Not Turn OverEngine Backfires Engine Lacks PowerEngine Runs Irregularly, Stalls, or Misfires Engine Pings or KnocksPossible Lean Solution Fuel Cause No Power at DC ReceptacleEngine Stops or Loses Power No Power at AC ReceptaclesAbout this Warranty Document Warranty Registration Form WarrantyWarranty Period Warranty Exclusions Polaris Power Generator Owner Responsibility Important Notice DATE/HOURS Service Comments Supplier Permormed Technician Maintenance LOGLabel Location IndexIndex PMS