Page 38

OPERATION

Safe Operating Precautions

Standby Power

Improper connection to a building electrical system can allow current from the generator to back feed into the utility lines. Such back feed may electrocute utility company workers or others who contact the lines during a power outage. Additionally, the generator may explode, burn, or cause fires when utility power is restored. Consult the utility company or a qualified electrician prior to making any power connections.

Connections to a Building Electrical System

Connections for standby power to a building's electrical system must be made by a qualified electrician and must comply with all applicable laws and electrical codes. Improper connections can allow electrical current from the generator to back feed into the utility lines. Such back feed may electrocute utility company workers or others who contact the lines during a power outage; when utility power is restored, the generator may explode, burn, or cause fires in the building's electrical system. Do not connect this generator to an automatic transfer switch. Serious damage to the engine and inverter module may result.

In some areas, generators are lawfully required to be registered with local utility companies. Check local regulations for proper registration and usage procedures.

System Ground

To prevent electrical shock from faulty appliances, the generator should be grounded. Connect a length of heavy cable between the generator's ground terminal and an external ground source.

System Requirements

There may be federal or state regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.

If the generator is used at a construction site, there may be additional regulatory requirements.

37

Image 38
Contents Polaris Power Table of Contents Introduction WelcomeIntended Use Safety Precautions Signal Words and Safety Terms Alcohol or Drug USEIdentification Numbers and Locations P1000iP2000iGeneral SafetySafety Warnings and Precautions Before and During OperationFire Safety Operator Safety Fuel Safety Carbon Monoxide Safety Electrical Safety Extension Cord Information Equipment ModificationsOutdoor Use only Danger Label Safety Labels and LocationsCarbon Monoxide Warning Hot Exhaust CautionSafety Controls and Features Generator ComponentsControl Panel Components P1000i P2000iFuel Tank Cap Vent Lever Engine Fuel SwitchChoke Lever Starter Recoil GripSmart Throttle Switch DC Receptacle and FuseAC Receptacles Indicator PanelGround Terminal Overload Protector Reset Switch Parallel ReceptaclesFirst USE Instructions Adding Engine OilFuel Recommendation Adding Fuel Pre-Operation Checklist PRE-OPERATION InspectionFuel Recommendations Safe Operating PrecautionsOperation RefuelingRemove the fuel tank cap a Before Starting the Engine Starting the EnginePosition the engine switch to on Stopping the Engine AC Operation AC Capacity Wattage Reference Table Power Management DC OperationOperation Disconnecting the Battery Charging Cable Smart Throttle SystemStandby Power Connections to a Building Electrical SystemParallel operation procedure Parallel Generator OperationShutting off the generators High Altitude Use Carburetor ModificationAlterations Emission Control System InformationSource of Emissions Problems Affecting Emissions Replacement PartsMaintenance Importance of MaintenanceMaintenance Safety Safety PrecautionsPeriodic Maintenance Periodic Maintenance ChartOpening the Service Door Hour Initial Break-In Initial MaintenanceFuel System Fuel Line InspectionOFF Oil Level Inspection Engine OilOil Recommendation Oil Change Procedure Maintenance Air Filters Air Filter InspectionAir Filter Cleaning Air Filter ReplacementSpark Plug Inspection and Replacement Spark PlugGap should be 0.6 0.7 mm Transporting the Generator Transportation and StorageTransportation Storage Storage PreparationAccessing the Fuel Tank Draining Fuel from the Fuel Tank and Carburetor Fogging the Engine Storage Precautions Removing from StorageSpecifications General SpecificationsPolaris Lubricants and Maintenance Products Modified coefficient table of ambient condition powerWiring Diagrams P1000i Wiring DiagramP2000i Wiring Diagram Red Gray Brown White BlackEngine Will Not Turn Over TroubleshootingTroubleshooting Symptoms Engine Turns Over, but Will Not StartEngine Lacks Power Engine BackfiresEngine Pings or Knocks Engine Runs Irregularly, Stalls, or MisfiresNo Power at DC Receptacle Possible Lean Solution Fuel CauseNo Power at AC Receptacles Engine Stops or Loses PowerWarranty About this Warranty Document Warranty Registration FormWarranty Period Warranty Exclusions Polaris Power Generator Owner Responsibility Important Notice Maintenance LOG DATE/HOURS Service Comments Supplier Permormed TechnicianIndex Label LocationIndex PMS