Polaris P1000i, P2000i manual Ground Terminal, AC Receptacles, Indicator Panel

Page 21

CONTROLS AND FEATURES

Ground Terminal

The ground terminal (O) connects to the frame of the generator, metal parts that do not conduct current, and ground terminals of each receptacle. Consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances for the intended use of the generator before using the ground terminal.

AC Receptacles

The AC receptacles (P) provide connections for properly rated AC appliances, see page 62 for specifications.

Indicator Panel

Output Indicator

The output indicator (Q) illuminates GREEN when the generator is in normal operation and producing electrical power at the receptacles.

Overload Indicator

The overload indicator (R) illuminates RED if there is a short circuit in the connected appliance(s), or if the generator is overloaded. The light remains illuminated for 5 seconds, then the current to the connected appliance is shut off and the output indicator light (GREEN) extinguishes.

P1000i P2000i

Q

R

S

Low Oil Indicator

The low oil indicator (S) illuminates RED before the oil level falls below a safe limit and the detection system automatically stops the engine. When there is a low engine oil level at startup, the engine will be prevented from starting.

20

Image 21
Contents Polaris Power Table of Contents Welcome IntroductionIntended Use Safety Precautions Alcohol or Drug USE Signal Words and Safety TermsP1000iP2000i Identification Numbers and LocationsSafety Warnings and Precautions SafetyGeneral Before and During OperationFire Safety Operator Safety Fuel Safety Carbon Monoxide Safety Electrical Safety Equipment Modifications Extension Cord InformationCarbon Monoxide Warning Safety Labels and LocationsOutdoor Use only Danger Label Hot Exhaust CautionSafety Generator Components Controls and FeaturesP1000i P2000i Control Panel ComponentsChoke Lever Engine Fuel SwitchFuel Tank Cap Vent Lever Starter Recoil GripDC Receptacle and Fuse Smart Throttle SwitchIndicator Panel Ground TerminalAC Receptacles Parallel Receptacles Overload Protector Reset SwitchAdding Engine Oil First USE InstructionsFuel Recommendation Adding Fuel PRE-OPERATION Inspection Pre-Operation ChecklistOperation Safe Operating PrecautionsFuel Recommendations RefuelingRemove the fuel tank cap a Starting the Engine Before Starting the EnginePosition the engine switch to on Stopping the Engine AC Operation AC Capacity Wattage Reference Table DC Operation Power ManagementOperation Smart Throttle System Disconnecting the Battery Charging CableConnections to a Building Electrical System Standby PowerParallel Generator Operation Parallel operation procedureShutting off the generators Carburetor Modification High Altitude UseEmission Control System Information Source of EmissionsAlterations Replacement Parts Problems Affecting EmissionsImportance of Maintenance MaintenanceSafety Precautions Maintenance SafetyPeriodic Maintenance Chart Periodic MaintenanceOpening the Service Door Fuel System Initial MaintenanceHour Initial Break-In Fuel Line InspectionOFF Engine Oil Oil RecommendationOil Level Inspection Oil Change Procedure Maintenance Air Filter Inspection Air FiltersAir Filter Replacement Air Filter CleaningSpark Plug Spark Plug Inspection and ReplacementGap should be 0.6 0.7 mm Transportation and Storage TransportationTransporting the Generator Storage Preparation StorageAccessing the Fuel Tank Draining Fuel from the Fuel Tank and Carburetor Fogging the Engine Removing from Storage Storage PrecautionsGeneral Specifications SpecificationsModified coefficient table of ambient condition power Polaris Lubricants and Maintenance ProductsP1000i Wiring Diagram Wiring DiagramsRed Gray Brown White Black P2000i Wiring DiagramTroubleshooting Symptoms TroubleshootingEngine Will Not Turn Over Engine Turns Over, but Will Not StartEngine Backfires Engine Lacks PowerEngine Runs Irregularly, Stalls, or Misfires Engine Pings or KnocksPossible Lean Solution Fuel Cause No Power at DC ReceptacleEngine Stops or Loses Power No Power at AC ReceptaclesAbout this Warranty Document Warranty Registration Form WarrantyWarranty Period Warranty Exclusions Polaris Power Generator Owner Responsibility Important Notice DATE/HOURS Service Comments Supplier Permormed Technician Maintenance LOGLabel Location IndexIndex PMS