Installation (contd.) | 14 |
WATER CONNECTIONS
Reversible Inlet/Outlet Connection
The MiniMax Plus heater is factory assembled with right side inlet/outlet water connections. The inlet/ outlet header can be reversed for left side water connections without removing the heat exchanger.
Reversing Water Connections Disassembly
Tools needed:
1/4 in Nut Driver
9/16 in. Socket and Wrench 1/2 in. & 9/16 in. Open Wrench
1.Remove the inspection plates.
2.Disconnect all wires from the
3.Disconnect the pressure switch wiring.
4.Remove the temperature sensing bulb from the in/out header. Note: You may cut the wire bundle ties.
5.Exchange the in/out header with the return header. Replace the heat exchanger tube seals with new seals provided in the
6.Install the temperature sensing bulb by passing the wires through the hole provided on the left side of the brace panel. Route wires through the support bracket.
7.Reconnect all the high limit wires. Reconnect the pressure switch wiring. Route the wires through the same hole as the thermostat sensor wires.
8.Reinstall the inspection plates.
PLUMBING
VALVES
When any equipment is located below the surface of the pool or spa, valves should be placed in the circulation piping system to isolate the equipment from the pool or spa.
Check valves are recommended to prevent back siphon.
CAUTION
Exercise care when installing chemical feeders so as to not allow back siphoning of chemical into the heater, filters or pump.
|
|
| TO |
| PUMP |
|
|
| POOL |
|
|
| POOL | MANUAL |
| FILTER |
|
| ISOLATION |
|
| ||
| HEATER | 3 |
|
| |
| VALVE |
|
| ||
|
| 1 CHECK |
|
|
|
|
| VALVE |
|
|
|
|
|
| ISOLATION |
|
|
|
|
| VALVE |
|
|
1 | Optional. |
|
| VALVECHECK 2 |
|
2 | Required when installation is below water level. | FROM |
| ||
POOL | Figure 12. | ||||
3 | Required when flow rates exceed 120 gpm. |
|
PLUMBING CONNECTIONS
The MiniMax Plus heater has the unique capability of direct schedule 40 PVC plumbing connections. A
CAUTION
Before operating the heater on a new installation, turn on the circulation pump and bleed all the air from the filter using the air relief valve on top of the filter. Water should flow freely through the heater.
Do not operate the heater unless water in the pool/ spa is at the proper level.
MANUAL BY-PASS
Where the flow rate exceeds the maximum 120 GPM, a manual bypass should be installed and adjusted. After adjustments are made, the valve
handle should be removed to avoid tampering.
Model | Min. | Max. * |
|
|
|
150 | 20 | 120 |
|
|
|
195/200 | 20 | 120 |
|
|
|
250 | 30 | 120 |
|
|
|
300 | 30 | 120 |
|
|
|
350 | 40 | 120 |
|
|
|
400 | 40 | 120 |
|
|
|
* Do not exceed the maximum recommended flow rate for the connecting piping.
Table 6.
BELOW POOL INSTALLATION
If the heater is below water level, the pressure switch must be adjusted. This adjustment must be done by a qualified service technician.