Rev
POWERMAX WIRING DIAGRAM
. G
EXTERNAL BOND LUG
TERMINATE SUPPLY SAFETY GROUND WIRE (GREEN) HERE GROUND SCREW WITH PAINT CUTTING WASHER
CHASSIS
SHEET METAL
CHASSIS |
SHEET METAL |
HIGH LIMIT |
THERMAL SWITCHES |
GRN |
IF ORIGINAL FACTORY WIRING MUST BE REPLACED, INSTALLER MUST SUPPLY
UL OR CSA (IF CANADA) APPROVED WIRE, 18 GAUGE, 600V, 105 C TEMPERATURE RATING. THERMAL FUSE WIRING MUST BE REPLACED WITH UL OR CSA (IF CANADA) APPROVED WIRE, 18 GAUGE, 600V, 125 C TEMPERATURE RATING..
INTERCONNECTING WIRING TO APPLIANCE MUST CONFORM TO THE NATIONAL ELECTRICAL CODE OR SUPERCEDING LOCAL (WIRING) CODES.
THERMAL FUSE
RED
WHT/RED
T1 |
|
WATER PRESSURE
SWITCH
RED
RED
WHT
WHT
F1 | F2 |
RED | MV |
WHT | PV/MV |
BLU | PV |
IGNITION RETURN
PLUG
GAS VALVE
MV
PV/MV
PV
A-
WHT/BLK
BLK
W1 | W2 | GRN |
|
| RED | MV |
|
T2 | WHT |
| PLUG |
ORG |
| ||
| WHT | MV/PV |
|
| BLU | PV |
|
SPST. EXTERNAL ON/OFF SWITCH
GRN
1 | 5 4 3 2 1 2 | 6 | 3 2 1 | 1 | 2 | 3 | 4 | ORG |
P4 | P7 |
| PI0 |
| P11 |
|
|
|
IGNITION MODULE
MV
MV/PV
PV
GND (BURNER)
GND
24 V
SPARK
PowerMax Electronic Ignition Wiring Diagram
7
ORG
ORG
AIR PRESSURE
BLUE SWITCH
JUMPER REQUIRED IF NO REMOTE SWITCH 25D K .032 D.C TAB
J2 J3
CONTROL RELAY
CLOSE ON CALL
FOR HEAT
24V | PRESS | HLMT | TFUSE |
J4 |
| J7 |
|
1 | 1 |
|
|
AUX.
CONTACTS
|
|
| TPROBE |
J6 | J8 | J5 | J9 |
SPA | COM | POOL |
|
P6 | P8 | P5 | P9 |
VLV | IGN MODULE |
JI0 | J11 |
1 | 1 |
THERMOSTAT
CIRCUIT BOARD
IGNITION WIRE
SPARK IGNITER
GRN 24 VAC RELAY
FAN
MOTOR
WHTBLK
120 VAC
BLK
TEMPERATURE
BLKPROBE
POOL OFF SPA
THERMOSTAT SELECT SWITCH
P/N 471048