Operation (contd.) | 6 |
|
|
MINIMAX PLUS ELECTRONIC IGNITION LIGHTING/OPERATION - PROPANE
FOR YOUR SAFETY: READ BEFORE LIGHTING
NOTE
The MiniMax Plus propane models have special features for additional safety and protection. Read the safety instructions for natural gas (page 5) before proceeding.
WARNING
If you do not follow these instructions exactly, a fire or explosion may result causing personal injury, loss of life and property damage.
Since propane gas is heavier than air, escaping propane will accumulate and remain at ground level. Do not attempt to light the heater. If you suspect a propane leak, lighting the heater can result in a fire or explosion which can cause personal injury, death, and property damage.
WHAT TO DO IF YOU SMELL GAS
-Do not try to light matches or lighter.
-Do not try to light any heater.
-Do not touch any electrical switch; do not use any phone in your building.
-Shut off gas line at propane tank.
Safety Lockout:
-Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
-If you cannot reach your gas supplier, call the Fire Department.
-Do not tamper with the heater because it is dangerous and voids all warranties.
This MiniMax Plus Propane Heater is equipped with a 100% safety lockout feature. If the pilot does not light within a maximum of 90 seconds, lockout will occur.
OPERATING INSTRUCTIONS
1.STOP! Read the safety information above.
2.Set the thermostat to the lowest setting.
3.Turn off electric power to the heater.
4.This heater is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
5.Remove the control access door.
6.Push in gas control knob slightly and turn clock-
wise to “OFF”.
7.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety information on page 5. If you don't smell gas, go to the next step.
8.Turn knob on gas control counterclockwise to “ON”; see Figure 2.
9. Replace the control access door.
10.Turn on the electrical power to the heater.
11.Set the thermostat to the desired setting.
12.If the heater will not operate, follow the instruc- tions "To Turn Off Gas To Heater" and call your service technician or gas supplier.
Gas
Inlet
ON
OFF
Figure 2. Gas control knob shown in “ON” position.
TO TURN OFF GAS TO APPLIANCE
1.Set the thermostat to lowest setting.
2.Turn off all electric power to the heater if service is to be performed.
3.Remove control access door.
4.Push in gas control knob slightly and turn
clockwise to "OFF". Do not force.
5.Replace control access door.
P/N 471048 | Rev. G |