Troubleshooting - General
Possible Cause | Remedy |
|
|
Heater will not come on |
|
|
|
Automatic ignition system fails | Check if electrical connections are |
| correct and securely fastened – |
| If YES, call serviceperson. |
Pump not running | Place pump in operation |
Pump air locked | Check for leaks |
Filter dirty | Clean filter |
Pump strainer clogged | Clean strainer |
Defective wiring or connection | Repair or replace wires |
Defective pressure switch | Replace switch |
Defective gas controls | Call serviceperson |
Turn switch to "ON" | |
Heater Short Cycling (Rapid On and Off Operation) | |
|
|
Insufficient water flow | Clean filter and pump strainer |
Defective wiring | Repair or replace wiring |
Defective flow valve or out of adjustment | Call serviceperson |
Defective | Call serviceperson |
Heater Makes Knocking Noises,
Make sure all valves on system are open
Heater operating after pump has shut off | Shut off gas supply and call serviceperson |
Heater exchanger scaled | Shut off gas supply and call serviceperson |
CAUTION
Please consult the latest edition of the “MiniMax Plus Service Manual” for complete service and repair instructions. Repairs should only be attempted by properly trained service personnel.