Installation (contd.) | 20 |
|
|
Draft Hood
Top Cover
Adaptor
Screw
(2 PLC's)
HEATER
Figure 24.
INDOOR DRAFT HOOD INSTALLATION
1.Take out the louvered outer top piece after first removing the sheet metal screws, attaching it to the cabinet.
2.Install the adaptor (vent kit).
3.Install the top cover (vent kit).
4.Install the draft hood (vent kit).
Use the provided screws to secure the vent assembly.
ELECTRICAL, IID ELECTRONIC UNITS
Electrical Rating |
|
60 Hz | 115 V.A.C. or 230 V.A.C. |
50/60 Hz | 208 V.A.C. or 240 V.A.C. |
NOTE
If any of the original wiring supplied with this heater must be replaced, installer must supply (No. 18 AWG 105° C. U.L. approved AWM low energy stranded) copper wire or it's equivalent.
In Canada: wires must be CSA approved.
WARNING
The heater must be electrically grounded and bonded in accordance with local codes or, in the absence of local codes, with the latest national electrical codes ANSI/NFPA No. 70.
In Canada: CSA standard C22.1 Canada Electrical Code Part 1 and/or local codes.
Always use crimp type connectors when connecting two wires.
This heater is equipped with a reversible junction box to allow line voltage to be wired from either side.
Transformer Wiring Instruction
Figure 26.
Figure 25.
P/N 471048 | Rev. G |