Pentair MiniMax Plus HP Series For Your Safety Read Before Lighting, Operating Instructions

Page 5
FOR YOUR SAFETY: READ BEFORE LIGHTING

Operation (contd.)

5

 

 

MINIMAX PLUS ELECTRONIC IGNITION LIGHTING/OPERATION - NATURAL GAS

FOR YOUR SAFETY: READ BEFORE LIGHTING

WHAT TO DO IF YOU SMELL GASWARNING

If you do not follow these instructions exactly, a fire or explosion may result causing personal injury, loss of life and property damage.

Do not attempt to light the heater if you suspect a natural gas leak. Lighting the heater can result in a fire or explosion which can cause personal injury, death, and property damage.

A.This heater is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

B.BEFORE OPERATING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

-Do not try to light any heater.

-Do not touch any electrical switch; do not use any phone in your building.

-Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

-If you cannot reach your gas supplier, call the Fire Department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it. Call a qualified service technician. Forced or attempted repair may result in a fire or explosion.

D.Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.

E.The MiniMax Plus incorporates (9) nine indicator lights to aid you in the operation of the heater, and to assist in diagnosing a failure in the heater’s function.

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat to the lowest setting.

3.Turn off electric power to the heater.

4.This heater is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

5.Remove the control access door.

6.Push in gas control knob slightly and turn clock-

wise OPERATING INSTRUCTIONS to “OFF”.

7.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step.

8.Turn knob on gas control counterclockwise TO TURN OFF GAS TO APPLIANCE to “ON”; see Figure 1.

9. Replace the control access door.

10.Turn on the electrical power to the heater.

11.Set the thermostat to the desired setting.

12.If the heater will not operate, follow the instruc- tions "To Turn Off Gas To Heater" and call your service technician or gas supplier.

Gas

Inlet

ON

OFF

Figure 1. Gas control knob shown in “ON” position.

TO TURN OFF GAS TO APPLIANCE

1.Set the thermostat to lowest setting.

2.Turn off all electric power to the heater if service is to be performed.

3.Remove control access door.

4.Push in gas control knob slightly and turn

clockwise Manual background to "OFF". Do not force.

5.Replace control access door.

Rev. G 1-22-04

P/N 471048

Image 5
Contents OPERATION & INSTALLATION MANUAL MiniMax Plus and PowerMaxFor Your Safety FOR YOUR SAFETY - READ BEFORE OPERATINGTable of Contents Pool and Spa Heaters IntroductionCODE REQUIREMENTS IMPORTANT NOTICESOperation WARRANTY INFORMATIONSAFETY RULES OPERATING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGTO TURN OFF GAS TO APPLIANCE WHAT TO DO IF YOU SMELL GASSafety Lockout Gas control knobs shown in “OFF” position LIGHTING INSTRUCTIONSWHAT TO DO IF YOU SMELL GAS OPERATING CONTROLS INDICATOR LIGHT DESCRIPTIONTHERMOSTAT ADJUSTMENT POWER THERMOSTAT SELECT SWITCHHEAT HEAT TROUBLESHOOTING CONTROLSSERVICE SERVICE IS IN THERMAL FUSE CIRCUIT TROUBLESHOOTING CONTROLS - ContinuedHEATER FIRING - NORMAL OPERATION MAINTENANCE INSTRUCTIONS MaintenanceENERGY SAVING TIPS SPRING AND FALL OPERATIONpH Chart CHEMICAL BALANCEpH Control Chart POOL AND SPA WATERSPECIFICATIONS Installation InstructionsOutdoor installation - stackless Outdoor installation - with vent kitPLUMBING WATER CONNECTIONSPLUMBING CONNECTIONS BELOW POOL INSTALLATIONQUICK-FLANGEINSTALLATION INSTRUCTIONS GAS LINE INSTALLATIONS GAS CONNECTIONSA manual main shut-offvalve must be installed externally to the heaterOUTDOOR INSTALLATION ONLY VENTILATIONOUTDOOR VENT CAP INSTALLATION STACK TYPE OUTDOOR VENT KITWater Connection Front24 in RemainingAir supply requirements below apply to all MiniMax heaters, including PowerMax versionsSTACK TYPE INDOOR DRAFT HOOD KIT Transformer Wiring Instruction INDOOR DRAFT HOOD INSTALLATIONELECTRICAL, IID ELECTRONIC UNITS Draft Hood Top Cover Adaptor Screw 2 PLCs HEATERMiniMax Plus Electronic Ignition Wiring DiagramMiniMax Plus WIRING DIAGRAM REMOTE SWITCH DUAL THERM IID ONLY MiniMax Plus Millivolt Wiring Diagram3 Wire Remote 2 Wire RemoteTroubleshooting - General INNER TOPS MINIMAX PLUS HEATER - ALL MODELSModel No 470024195/200 MiniMax Plus Only Parts ListDESCRIPTION DESCRIPTION MiniMax Plus Only Parts List, contd195/200 Not ShownOPERATION & INSTALLATION MANUAL PowerMax Pool & Spa HeaterINSTALLER AFFIX THESE INSTRUCTIONS APPENDIXPool and Spa Heater PowerMaxPRESSURE SWITCH OPERATION MOUNTING ASSEMBLYDESCRIPTION OF SYSTEM OPERATION SYSTEM OPERATIONReduced Maximum Equivalent Vent Run feet VENTINGVent for roof penetration installations INDOOR INSTALLATIONS POWERMAX VENTING GUIDELINESVent termination for side wall installations DIAGRAMVent Termination OUTDOOR INSTALLATION POWERMAX VENTING GUIDELINESThe Vent Pipe POWERMAX WIRING DIAGRAM ASSEMBLY TO A POOL HEATER WITH IID IGNITION INSTRUCTION FOR WIRING A POWERMAX INDUCED DRAFTWIRING DIAGRAM FOR POWERMAX KIT A-10 POWERMAX HEATER - ALL MODELSOPTIONAL OUTDOOR VENT 195/200 PowerMax Heater Only Parts ListDESCRIPTION Not Shown PowerMax Heater Only Parts List, contdDESCRIPTION DESCRIPTION PowerMax Assembly Parts ListPowerMax Assembly Pentair Pool Products, Inc SAVE THESE INSTRUCTIONS