Raypak 336A, 406A, 206A, 407A, 337A, 207A, 267A, 266A operating instructions Call OUT Description

Page 52

ATMOSPHERIC HEATERS

CALL

 

 

 

 

 

OUT

DESCRIPTION

206A

266A

336A

406A

HM

HEAT EXCHANGER - METAL

 

 

 

 

1-HM

Heat Exchange Assy.Copper ASME CI

010051F

006727F

010053F

010054F

 

Heat Exchange Assy.Cupro Nickel ASME CI

010360F

010361F

010362F

010363F

2-HM

Inlet/Outlet Header ASME CI

006730F

006730F

006730F

006730F

15-HM

Inlet & Outlet Flange

003766F

003766F

003766F

003766F

16-HM

Flange Gasket 1 1/2" Connections

062236B

062236B

062236B

062236B

 

Flange Gasket 2" Connections

800080B

800080B

800080B

800080B

3-HM

Return Header ASME CI

006731F

006731F

006731F

006731F

4-HM

Tube Bundle Copper ASME *

010055F

006733F

010057F

010058F

 

Tube Bundle Cupro Nickel ASME *

010368F

010369F

010370F

010371F

5-HM

Baffle

010038F

005261F

010040F

010041F

6-HM

Stud Bolt Kit

007870F

007870F

007870F

007870F

7-HM

Header Gasket (9)

800014B

800014B

800014B

800014B

8-HM

Unitherm Governor

062234B

062234B

062234B

062234B

9-HM

U.G. Retainer Spring

850254

850254

850254

850254

10-HM

Bypass Valve

062235B

062235B

062235B

062235B

11-HM

Bypass Spring

850252

850253

850253

850253

12-HM

Drain Valve

500719

500719

500719

500719

13-HM

Sensor Well

003765F

003765F

003765F

003765F

14-HM

Well Retaining Clip

300203

300203

300203

300203

17-HM

Rear Drain Plug & Cover

005264F

005264F

005264F

005264F

J

CONTROL BOX

 

 

 

 

1-J

Transformer 120/240/24V

006736F

006736F

006736F

006736F

2-J

Rocker Switch

009493F

009493F

009493F

009493F

M

MISCELLANEOUS COMPONENTS

 

 

 

 

1-M

Pressure Switch 1.75 PSI

006737F

006737F

006737F

006737F

 

Pressure Switch 11 PSI Special-See Water Pressure Switch Adj.

009133F

009133F

009133F

009133F

2-M

Thermostat Knob

009499F

009499F

009499F

009499F

3-M

Thermostat Shaft MV

800307

800307

800307

800307

4-M

Knobstop

006886F

006886F

006886F

006886F

5-M

Thermal Fuse

005899F

005899F

005899F

005899F

6-M

PRV 125 PSI (Optional)

008091F

007224F

007224F

007224F

7-M

Deliming Kit

052871F

052871F

052871F

052871F

8-M

Wire/Harness Millivolt

010386F

010386F

010386F

010386F

 

Wire/Harness IID

009490F

009490F

009490F

009490F

9-M

Control Bezel MV (Includes Dial Decal)

009489F

009489F

009489F

009489F

10-M

Dial Decal MV

009858F

009858F

009858F

009858F

11-M

Control Bezel IID (Includes Switch Decal)

009491F

009491F

009491F

009491F

12-M

Switch/Decal-Membrane

009492F

009492F

009492F

009492F

13-M

Control Bezel Cover

009487F

009487F

009487F

009487F

14-M

Gasket Insulation (Swaybrace & Jacket Top)

010350F

010350F

010350F

010350F

15-M

Touch-up Paint (Green)

750125

750125

750125

750125

 

Touch-up Paint (Dark Gray)

750126

750126

750126

750126

16-M

Tie Down Bracket (Optional)

011636

011636

011636

011636

P

PILOT

 

 

 

 

1-P

Pilot Nat. MV

600525B

600525B

600525B

600525B

 

Pilot Pro. MV

600575B

600575B

600575B

600575B

2-P

Pilot Nat & Pro IID

002003F

002003F

002003F

002003F

3-P

Pilot Orifice Nat. MV

003901F

003901F

003901F

003901F

 

Pilot Orifice Pro. MV

003902F

003902F

003902F

003902F

4-P

Pilot Orifice Nat. IID .020

003903F

003903F

003903F

003903F

 

Pilot Orifice Pro. IID .012

004308F

004308F

004308F

004308F

5-P

Pilot Generator MV

600019B

600019B

600019B

600019B

6-P

Pilot MTG Bracket MV

010352F

010352F

010352F

010352F

7-P

Pilot Mounting Bracket IID

306692

306692

306692

306692

8-P

Lighter Tube (MV Units Only)

062996

062996

062996

062996

9-P

Pilot Tube

004078F

004078F

004078F

004078F

10-P

Hi Tension Wire IID with Pilot Electrode

007864F

007864F

007864F

007864F

11-P

Pilot Shield

010351F

010351F

010351F

010351F

R

REFRACTORY

 

 

 

 

1-R

Refractory Common Lt & Rt

010088F

010088F

010088F

010088F

2-R

Refractory Uncommon (Front & Rear)

010089F

010090F

010091F

010092F

3-R

Refractory Retainer Kit

010387F

010388F

010389F

010390F

*WARNING: The Hydraulic conditions or water chemistry that caused the tube bundle to fail have very likely also damaged the bypass valve and Unitherm Governor. We recommend you replace the Unitherm Governor and inspect the bypass assembly. Failure to do so could cause premature failure of this replacement part.

52

Image 52
Contents Installation and Operating Instructions What to do if YOU Smell GASWater Chemistry MaximumContents For Your Safety Read Before Operating START-UP ProceduresBefore START-UP Burners Water Millivolt System Operating Instructions and SHUT-OFF Procedures SHUT-OFF ProceduresElectronic Ignition System Automatically Lighted PilotAfter START-UP Water Pressure SwitchVisual Inspection Atmospheric Heaters Maintenance and Care Procedures See plumbing diagramIf Heater will not Fire Pool & SPA Water ChemistryCold Weather Operation Important Freeze InformationWinterizing the Pool & SPA Heater Part TWO Installation and Service Instructions Receiving EquipmentGeneral Specifications Installation InstructionsImportant Notice Code RequirementsOutdoor Installation Outdoor Heater InstallationClearances ALL Heaters10 ft Florida Building Code Wind Speed = 150 MPH, 3 Second Gust Exposure = CIndoor Heater Installation Outdoor Stack Indoor StackSpecifications and Dimensions Atmospheric UnitsLow NOx Units Power Vent Kit Model Part No Combustion and Ventilation AIR Indoor Units OnlyModel Square Inches Vent PipingB149.1 and B149.2 GAS Supply ConnectionsGAS Pressure Regulator GAS Pressure Adjustment LocationsPipe Sizing for GAS Connections Flow Rates Plumbing for Water ConnectionsPolymer Headers Cast Iron Headers Asme INLET/OUTLET Header Polymer Cast Iron Headers Asme ModelsINLET/OUTLET Header Asme Unitherm Governor OperationAuxiliary Bypass Valve Adjustment External Auxiliary Bypass ValveCast Iron Header Asme Models Heat Exchanger Reversal Procedure Standard Models Fig. #4Electrical Wiring Millivolt ModelsDigital Models Atmospheric120V Atmospheric Heater Transformer Wiring VAC Wiring240V Atmospheric Heater Wiring Diagram Millivolt Mechanical Thermostat Wiring Diagram Digital Models Atmospheric Wiring Diagram Digital Models LOW NOx General Location of Controls Atmospheric Servicing InstructionsLOW NOx Control Adjustments Millivolt Models Control Adjustments Digital ModelsControl Panel Removal Digital Thermostat Controls Thermostat Control OperationSETdef Default Settings RESfl Reset Fault HistoryProgram Button Cfff Fahrenheit to CelsiusDiagnostics Reading a Fault Fault CodesStatus Codes Program Modes Display DefinitionRemote Operation Remote Control Installation and OperationActivating the Remote Remote Control Wiring Wire Remote Control On-OffFlame ROLL-OUT Safety Switch Pilot Safety Millivolt ModelsPilot Safety Digital Models High LimitsPilot Removal and Cleaning Burner Tray RemovalGAS Valve Removal Main Burner and Orifice RemovalTube Cleaning Procedure Desooting ProcedureImmersion Well Replacement Unitherm Governor U.G. ReplacementBlower Adjustment LOW NOx Pool HeatersOperation Visual InspectionPilot Removal Combustion Blower RemovalTroubleshooting MechanicalPage Electrical Electronic Ignition IID For qualified technicians onlyDigital Control Logic Flow Chart YESManufacturer Replacement PartsEastman Avenue OXNARD, CA Atmospheric Heaters LOW NOx Heaters IID LOW NOx Pilot Call OUT Description Call OUT Description Sheetmetal Call OUT Description 267A