ELECTRICAL - STANDING PILOT MILLIVOLT
POOL OR SPA HEATER
ELECTRICAL CHECK WITH MILLIVOLT GAS VALVE
CAUTION: For qualified service personnel only.
1.Filter must be on with adequate water flow through heater.
2.Gas valve must be in "ON" position. Thermostat set higher than pool water temperature.
3.Jumpers are for temporary check only. If left in place, they could cause the heater to burn up.
Light pilot
If pilot burner remains lit
Jump across both "TH"
wires on gas valves
|
|
|
|
|
|
|
|
|
If main burner fires, |
| If main burner does not |
| Replace | ||||
remove jumper |
| fire, remove jumper |
| gas | ||||
|
|
|
|
|
|
|
| valve |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
If pilot burner goes out when main burner lights or when gas valve knob is released
Remove both "TH"
wires from gas valve.
Relight pilot
If pilot burner does not light
Check gas supply, gas line size, gas pressure. Also check for insects or debris in pilot output
| Jump across pressure | ||||||||
|
| switch | terminals | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
If main burner fires, |
|
|
| If main burner does not | |||||
remove jumper |
|
|
| fire, remove jumper | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Clean filter |
|
|
| Jump across thermostat | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
If pilot burner stays on
Problem is a wire or component short to cabinet or low gas pressure
If burner does not remain lit, attach millivolt meter and read pilot output
If above 500mV, replace gas valve
Check for adequate water
flow from filter
Replace pressure switch
If main burner fires,
remove jumper
Replace thermostat
If main burner does
NOT fire...
Jump across each
high limit and remove
jumper
Replace high limit that caused heater to fire
If below 500mV, check gas pressure. Also check for insects or debris in the pilot burner
If output is still low, replace pilot generator
1Raw Output (700mV± 100)
Pilot generator disconnected from valve (knob must be held down to keep pilot on).
White – Negative Red + Positive
2Pilot Load (500mV± 100)
Pilot generator connected to
PP(Power
TH PP – Common
3Main Valve Load (200mV± 100)
Control/Limit circuit closed (All switches "ON")
PP(Power
TH PP – Common