Raypak P-1826 manual Servicing, General Location Of Controls, Temperature Control, Pressure Switch

Page 24
SERVICING

SERVICING

General Location Of Controls

Models 926-1826

Inlet/Outlet

Pressure

Header

Switch

Unitherm

Electrical

Governor

Conn.

Hi-limit

 

control/

 

Temp. Control

Main Burner Gas Valve

Fig. 28: General Location of Controls

(Models 926-1826)

Models 2100-4001

Inlet/Outlet

Header w/Bypass

Pump

Electrical

Connection

 

Main

Burner

Manual On/Off Valve

Gas

Valve

Fig. 29: General Location of Controls

(Models 2100-4001)

Temperature Control

The pool water temperature is controlled by the pool thermostat. The heater water temperature high limit is controlled by the manual reset high limit.

Pressure Switch

The pressure switch, or heater actuator on Models 926-1223 equipped with a Unitherm Governor, ensures that the heater operates only when the filter pump is in operation. It is factory set at 1.75 PSI for deck level installations. When the heater is located below the level of the spa or pool, it may be necessary to reset the pressure switch to compensate for the no- flow static head. If it is necessary to reset the pressure switch, we recommend the following procedure.

Pressure Switch Adjustment

1.Make sure the pool filter is clean before adjusting the switch.

2.Set the heater control to the OFF mode.

3.Turn the filter pump on and confirm that the pres- sure switch is closed (use a multimeter to check). If the pressure switch fails to close, either the switch setting is too high or the filter pump is not supplying enough pressure.

4.Turn the heater ON.

5.Manually turn the pressure adjustment knob clock- wise until the heater shuts off. (A flat screw driver may be necessary if knob is too tight).

6.Slowly turn the adjustment knob counter-clock- wise until the heater calls for heat again.

7.Turn an additional 1/2 turn counter-clockwise.

8.While the heater is running, check the adjustment by turning the pump off and on several times. The burners should shut off immediately when the pump is turned off. If it does not, repeat the above steps until proper operation is observed.

24

Image 24
Contents INSTALLATION & OPERATING INSTRUCTIONS Raytherm Commercial Swimming Pool HeaterModels P-926to P-1826 & P-2100to P-4001 Corrosive water voids all warranties CONTENTS WARNINGS Pay Attention to These TermsDANGER RECEIVING EQUIPMENT INSTALLATION GENERAL SPECIFICATIONSBase Installation Code RequirementsClearances Combustion Air Indoor Units OnlyIndoor Heaters Outdoor HeatersVenting Connections Drafthood Indoor ModelsVent Piping Gas Supply Connections Gas Pressure RegulatorVenting of Diaphragm Gas Components Model1-1/4” 1-1/2”Flow Switch CONTROLSWater Connections Water Pressure Switch Automatic Chlorinators and Chemical FeedersUnitherm Governor Operation Companion Flange Connections ModelsModel No ConnectionMinimum Model No. Loop* Flow Rates Heater Flow2.Lace metal strapping or clamps, NOT PROVID- ED through the ¾” slots on the cover and fasten securely to pipe as shown in Fig. 15 & 16. Do not over-tightenclamps HEATER Models 0926 thru 1223 with UG RECOMMENDED FIELD INSTALLED ISOLATION VALVESFORSERVICEBLENDEDWATER TEMPERATURE THERMOMETERATHEATERINLETModels 2100 thru HEATEROUTLETTEMPERATURETHERMOMETERExternal Auxiliary Bypass Valve Where Required Auxiliary Bypass Valve Adjustment926-1223Models Only Temperature ControlsElectrical Wiring High & Low Gas Pressure SwitchesLow Water Cutoff Electronic IgnitionWiring Diagram-Models Wiring Diagram-Models Wiring Diagram-Models Wiring Diagram-Models Pressure Switch Pressure Switch AdjustmentSERVICING General Location Of ControlsSTART-UP PROCEDURES Pilot SafetyTwo-SpeedPumps Before Start-UpINSPECTION PROCEDURES After Start-UpBurners SERVICING PROCEDURES Tube Cleaning Procedure TypicalBurner Drawer Removal Gas Valve RemovalPilot Removal and Cleaning Heat Exchanger ReassemblyMain Burner and Orifice Removal Heat Exchanger RemovalControl Well Replacement Tube Replacement ProcedureProcedure For Cleaning Flue Gas Passageways Combustion Chamber RemovalMAINTENANCE AND CARE Unitherm Governor ReplacementUNITHERM GOVERNOR WITH POWER ELEMENT INLET/OUTLET HEADER OUTLET INLET GASKETWinterizing Your Heater TROUBLESHOOTING MECHANICAL FOR QUALIFIED SERVICE PERSONNEL ONLYIMPORTANT NOTICE or refer to heater sizing chart Reset time clockClean filter Refer to installation instructionsTROUBLESHOOTING HONEYWELL S8600 Intermittent Pilot SystemELECTRICAL ELECTRONIC IGNITION IID IID STARTLIMITED WARRANTY RAYTHERM TYPE P SIZES HEAT EXCHANGER WARRANTYADDITIONAL WARRANTY EXCLUSIONS PARTS REPLACEMENT