Outer jacket very hot (paint blistered)
Takes long time to heat pool or spa
Liming
Leaking at well.
Leaking at heat exchanger.
Gasket brittle and leaking- (overheated).
*Broken refractory caused by |
|
|
|
shipping damage or improper |
|
|
|
combustion………………………….. | Replace refractory panels. | ||
Excessive sooting of heat |
|
|
|
exchanger…………………………... | Determine cause of sooting & | ||
| correct. | ||
Calculatetemperature in °F/hr……... | Heat rise (°F/hr.) = Htr.output | ||
|
|
|
|
| Pool gallonage x 8.33 | ||
| or refer to heater sizing chart. | ||
| This does not take into account heat | ||
| loss due to weather. | ||
Filternotrunning longenough…….... | Reset time clock. | ||
Dirty filter…………………………….. | Clean filter. | ||
Gas line or meter under- |
|
|
|
sized……… | Refer to installation instructions. | ||
Bypassing too much water……….... | Inspect bypass for movement, if no | ||
| movement, replace. | ||
U/Gnotfunctioning……………… | Replace if no movement when | ||
| heated. | ||
Overacid………………………… | Replace well and maintain water | ||
| chemistry properly. | ||
Overacid……………………………... | Replace heat exchanger and main- | ||
| tain chemistry properly. | ||
Heater running after pump |
|
|
|
shuts off……………………………... | See pressure switch adjustment. | ||
Refractorydamage…………………. | Replace refractory. | ||
Sooted heater……………………….. | Determine cause of sooting and cor- | ||
| rect. | ||
*Usually occurs on initial |
|
|
|
33