FUNCTION TESTS

Function Tests

Setup

1Position the machine on a firm surface directly below the desired work area.

2Connect to the appropriate power source: DC models: Connect the battery pack.

AC models: Connect to a grounded 15A AC power supply. Use a 12 gauge / 3.3mm2 3-wire grounded extension cord no longer than

50 feet / 13 m.

Air models: Connect the air line.

3Insert the key and turn to platform control.

4Pull out the red Emergency Stop button to the on position at the ground controls.

5Twist to release the red Emergency Stop button at the platform controls.

Result: AC & DC models: The power light should come on.

Air models: The air pressure gauge should read 80-110 psi /5.5 - 7.8 bar.

6Select an outrigger and slide it into a base socket until the outrigger lock pin snaps into place. Adjust the outrigger to level the machine and raise the base casters slightly off the ground. Level the machine using only the outriggers.

7Check the interlock display lights at the ground controls. Confirm that the corresponding light is on.

8Repeat this procedure for each of the remaining outriggers.

9Use the bubble level and adjust the leveling jacks until the machine base is level.

Test Emergency Stop

10Push in the red Emergency Stop button at the ground controls to the off position.

11Push in the control activate button and rotate the up/down switch in the direction of intended travel.

Result: The up/down function should not operate.

16

Genie AWP Super Series

Part No. 114002

Image 18
Contents Operator’s Manual Contents Contact usSafety Rules Do Not Operate UnlessElectrocution Hazards Tip-over HazardsMaximum allowable side force Fall Hazards Collision HazardsExplosion and Fire Hazard Improper Use HazardBodily Injury Hazard Damaged Machine HazardsBattery and Charger Safety DC Models Burn Hazards Explosion HazardsLifting Hazard Decal Legend Controls Ground ControlsAC and DC Models Air Models Platform Controls Page Pre-operation Inspection Breather Cap AC & DC ModelsFundamentals Pre-operation Inspection PRE-OPERATION InspectionMaintenance Check the Battery DC ModelsObserve and Obey Check the Hydraulic Oil Level Check the Tire Pressure RT Base ModelsScheduled Maintenance Check the Oil Lubricator Canister Drip Rate Air ModelsCheck the Air Filter/Regulator Canister Air Models Function Tests Function Tests Setup Test Emergency StopTest Outrigger Interlock Workplace Inspection Workplace InspectionOperating Instructions Manual Lowering Emergency StopPlatform Raise and Lower Auxiliary Platform Lowering AC & DC ModelsTo Charge Battery Battery Charging InstructionsBattery and Charger Instructions Observe and Obey Dry Battery Filling Charging InstructionsTransport Instructions Transport Instructions Observe and ObeyLifting Instructions Loading for Transport Transport InstructionsSecuring the Machine Winching the Machine onto a Flatbed TruckLoading the Machine With a Crane Tilt-back Operation Instructions Tilt-back Operation Instructions Observe and obeyTilt-back Frame Lowering the Tilt-back Assembly Tilting Back the MachineStowing the Tilt-back Assembly Returning the Machine to Standing PositionDecals Inspection for Decals with WordsModels with Tilt-back Frame Models without Tilt-back Frame Inspection for Decals with Symbols Models with Tilt-back Frame Models without Tilt-back Frame Specifications Machine SpecificationsSpecifications Genie Scandinavia