Third Edition • First Printing | Operator’s Manual |
|
|
|
|
12 Push in the red Emergency Stop button at the platform controls to the off position.
13 Pull out the red Emergency Stop button at the ground controls to the on position.
14Push in the control activate button and rotate the up/down switch in the direction of intended travel.
Result: The up/down function should not operate.
Test Outrigger Interlock
15Twist to release the red Emergency Stop button at the platform controls.
Result: The up/down functions should operate.
16Unscrew one leveling jack until the corresponding interlock display light turns off.
Result: The up/down function should not operate.
17Return the leveling jack to the previous setting and check the bubble level.
18Repeat this procedure for each outrigger.
Test Auxiliary Platform Lowering - AC & DC Models
19 Raise the platform slightly.
20Disconnect the power source from the machine.
21Turn the key switch to ground control.
22Push in the auxiliary platform lowering button at the ground controls.
Result: The platform should lower.
FUNCTION TESTS
23 Connect the power source to the machine.
24 Turn the key switch to platform control.
25 Raise the platform slightly.
26Disconnect the power source from the machine.
27Push in the control activate button and rotate the up/down switch in the down direction.
Result: The platform should lower.
28 Connect the power source to the machine.
Test Manual Lowering
29 Raise the platform slightly.
30Activate the manual lowering valve located at the bottom of the
hydraulic cylinder.
Result: The platform should lower.
Part No. 114002 | Genie AWP Super Series | 17 |