4-2) AC OUTPUT MEASURING
SWITCH
A
~
TO AC RECEPTACLE | F | V |
|
| ~ |
LOAD
Use a circuit above for measuring AC output. A hot plate or lamp with a power factor of 1.0 may be used as a load. Adjust the load and rpm, and check that the voltage range is as specified in the following table at the rated amperage and rated rpm.
Model |
| Specification |
| ||
|
|
|
| ||
120V / 60Hz | 220V / 50Hz | 230V / 50Hz | 240V / 60Hz | ||
| |||||
|
|
|
|
| |
RG2800i |
|
|
|
| |
RG3200i |
|
|
|
| |
RG4300i | |||||
RG2800iS | |||||
|
|
|
| ||
RG3200iS |
|
|
|
| |
RG4300iS |
|
|
|
| |
|
|
|
|
|
Voltage range
4-3) DC OUTPUT MEASURING
SW Load
To DC Terminal
Measurement of DC output is executed with the switch turned ON while the current is regulated at 8.3A by adjusting the load to the generator. If the voltage is within the range from 6V to 14V, the voltage output is normal.
NOTE : If a battery is connected as a load to the generator, the DC output voltage will increase by approximately 1 to 2 V.
Therefore, carefully observe the electrolyte level and do not overcharge the battery.
– 17 –