Subaru Robin Power Products RG4300IS Diode Rectifier, Checking table for analogue circuit tester

Page 23

(3)DIODE RECTIFIER

Yellow

Gray

Orange

 

 

Orange

Diode rectifier

 

Yellow

 

Yellow

 

 

 

Yellow

Gray

 

 

Circuit tester

The circuit inside the diode rectifiers is as shown in the chart above.

Check continuity between each terminal by using a circuit tester.

The rectifier is normal when continuity is as follows:

Checking table for analogue circuit tester

Analogue circuit tester

 

Apply black

 

needle of the circuit tester

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

Yellow

Orange

Gray

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

-

No continuity

No continuity

Continuity

 

 

 

 

 

 

 

 

 

 

 

 

Apply red

 

 

 

needle

Yellow

No continuity

-

No continuity

Continuity

of the circuit tester

Orange

Continuity

Continuity

-

Continuity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gray

No continuity

No continuity

No continuity

-

 

 

 

 

 

 

 

 

 

 

 

 

Checking table for degital circuit tester

Degital circuit tester

 

Apply red

 

 

 

needle of the circuit tester

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

Yellow

Orange

Gray

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

-

No continuity

No continuity

Continuity

 

 

 

 

 

 

 

 

 

 

 

 

Apply black

 

needle

Yellow

No continuity

-

No continuity

Continuity

 

of the circuit tester

Orange

Continuity

Continuity

-

Continuity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gray

No continuity

No continuity

No continuity

-

 

 

 

 

 

 

 

 

 

 

 

 

NOTE 1 : Because of the difference of measuring method between the analogue circuit tester and the digital circuit tester, polarity of tester needles should be reversed.

NOTE 2 : "Continuity" means forward direction characteristics of the diode, and different from short circuit condition

(in which a pointer of the tester goes out of its normal scale), shows resistance to some extent. When results of the checking indicates failure even in one section, replace with a new one.

NOTE 3 : Some analogue testers like "Simpson" brand operate as some as digital testers.

(4)AC RECEPTACLES

Check that no live part or wire or plastic part is burnt.

– 20 –

Image 23
Contents Generators Page Contents STD SpecificationsModel RG2800i RG3200i RG4300i NGK BR6HSModel RG2800iS RG3200iS RG4300iS External View of Generator Open Frame Type General DescriptionRG4300i RG2800iS External View of Generator Sound Proof TypeRG3200iS / RG4300iS 50Hz-240V Control Panel50Hz-230V 60Hz-120VMulti Monitor Engine SwitchLocation of Serial Number and Production Number Alternator Range of Applications Incandescent lamp, heater, etc. with a power factorMercury lamps with a smaller power factor Appliances without any indication as to power consumption Cross Allowable Cable Voltage drops per 30 meters of cable Ammeter Measuring and Checking ProceduresMeasuring Instruments VoltmeterTachometer Circuit TesterMeager Tester Dr.RobinPartNumber388-47565-08 SpecificationsModel DC Output Measuring AC Output MeasuringControl Panel Measuring Insulation ResistanceStator RG2800i RG3200i RG4300i RG2800iS RG3200iS RG4300iS Output Wires4P Connector Checking Functional MembersAC Receptacles Diode RectifierChecking table for analogue circuit tester Checking table for degital circuit testerFloat Type OIL Sensor DC Circuit BreakerPart Number Part Name Shape Usage Disassembly and AssemblyPreparation and Precautions Special ToolsStarter Handle Disassembly ProceduresFuel PIPES, Fuel Strainer and Battery Cables Side Cover L and RControl Panel and Inverter Unit Grounding WireChoke Wire For electric start modelsRear Cover Wire BandFuel Tank and Fuel System Parts Fuel TankAutothrottle Coupler Wire HarnessInverter Unit Components Control BOX and Inverter UnitComponents and Control BOX Components Control Panel Control BOX Components RG2800i / RG3200i / RG2800iSControl BOX Components RG4300i / RG3200iS / RG4300iS Muffler Foam Rubber InsulatorsMuffler Cover AIR Cleaner and Carburetor Soundproof Type Engine BlockOpen Frame Type Through Bolt and Rotor Alternator Components Bottom Extension Plate Blower HousingRecoil Starter Flywheel Drive Shaft and FANFor SOUND-PROOF Models Reassembly ProceduresMount Rubbers Sound InsulatorTightening torque 40-60 Kgf ・cm 4.4 Ft ・lbs Blower HousingFlywheel FAN and Drive Shaft Tightening torque 8.0-10.0 N・m 80-100 kgf・cm 5.9-7.4 ft・lbsThrough Bolt thread in reverse direction Recoil StarterTightening torque 6.5-8.5 N・m 65-85 kgf・cm 6.3 ft・lbs Rear CoverInstallation of Engine Alternator Assembly Onto Frame Tightening torque 6.0-8.0 N・m 60-80 kgf・cm 5.9 ft・lbs AIR Cleaner BaseAIR Cleaner Element CarburetorMuffler Cover MufflerControl BOX and Inverter Unit Grounding WiresConnection of Wiring Harness Tightening torque 4.0-6.0 N・m 40-60 kgf・cm 4.4 ft・lbs Clamping of the Choke Cable and Ground WiresAuto Throttle Fuel TankMuffler Cover Rear Rear Cover UpperGround Wire Side Cover Recoil Starter HandleRecoil Starter Disassembly proceduresDisassembly is completed Assembly procedure Five turns in counter-clockwise When Checking items after assemblyNo output power or Low output Trouble ShootingImproper revolutions Electronic throttle Engine does not start Start failure RG2800i / RG3200i / RG2800iS 50Hz-230V Recoil starter model Wiring DiagramRelay AC receptacle Earth ground terminal RG2800i / RG3200i / RG2800iS 50Hz-240V Recoil starter modelEngine 240V Switch Fuse10A RG2800i / RG3200i / RG2800iS 60Hz-120V Recoil starter model Engine 120V SwitchDiode DC output Terminal Rectifier Coil Page Lively Blvd. Wood Dale, IL 60191 Phone 630-350-8200 Fax
Related manuals