Subaru Robin Power Products RG4300IS, RG3200IS, RG2800IS Engine Switch, Multi Monitor

Page 11

(1) ENGINE SWITCH

RG2800i / RG3200i / RG2800iS

The engine switch is designed for easy operation with the interlocking

STOP

ENGINE SWITCH

mechanism between the fuel cock and the choke furnished.

 

RUN

 

To start the engine, turn the knob to the position.

 

CHOKE

 

(Choke valve is closed.)

 

CHOKE

 

 

 

 

 

 

Keep the knob in this position after the engine

RG4300i / RG3200iS / RG4300iS

 

starts. (The engine can be started with the knob at

 

(With electric starter)

RUN

this position when the engine is warm.)

 

ENGINE SWITCH

 

 

 

 

To stop the engine, return the knob to the position.

 

STOP

 

 

RUN

STOP

(The fuel cock is closed as well.)

 

 

 

 

START

 

 

 

(2) KEY SWITCH for electric starting models.

To start the engine with electric starter.

(3) MULTI MONITOR

LED display

Operation hour lamp

LED display

 

 

 

 

Voltage lamp

Operation hour, voltage and frequency are

 

MULTI MONITOR

Hours

indicated in turns by means of depressing the LED

 

 

 

 

 

 

V

Frequency

display changeover switch. In addition, "O_Lod"

 

 

 

 

 

 

Hz

lamp

(overload) will be indicated when the generator is

 

 

 

 

 

 

 

 

in the overload condition or appliance(s) is out of

 

AUTO

 

 

 

order.

Engine oil level

 

 

 

P-SAVE

 

 

In this case, stop the engine immediately and check

warning lamp

 

 

 

 

 

 

 

 

 

the appliance and/or generator for overloading.

 

 

 

 

 

After the check and remedy, restarting the engine

Auto-power

 

Auto-power

 

LED display

will resume displaying in the normal manner.

saving lamp

 

saving switch

 

changeover switch

Operation hour lamp

Lamp (red) is turned on when LED display is changed over into operation hour indication.

Voltage lamp

Lamp (red) is turned on when LED display is changed over into voltage indication.

Frequency lamp

Lamp (red) is turned on when LED display is changed over into frequency indication.

LED display changeover switch

When depressing this switch, indication in LED display is changed over in turns;

operation hour voltage frequency operation hour.

When starting the engine, operation hour is indicated in LED display at first.

Auto-power saving switch

When depressing this switch, auto-power saving function is activated.

Auto-power saving lamp

Lamp (green) is turned on while auto-power saving function is activated.

Engine oil level warning lamp

When the engine oil level is lower than the specified level, the lamp is turned on. Then engine will be stopped.

– 8 –

Image 11
Contents Generators Page Contents STD SpecificationsModel RG2800i RG3200i RG4300i NGK BR6HSModel RG2800iS RG3200iS RG4300iS External View of Generator Open Frame Type General DescriptionRG4300i RG2800iS External View of Generator Sound Proof TypeRG3200iS / RG4300iS 50Hz-240V Control Panel50Hz-230V 60Hz-120VMulti Monitor Engine SwitchLocation of Serial Number and Production Number Alternator Range of Applications Incandescent lamp, heater, etc. with a power factorMercury lamps with a smaller power factor Appliances without any indication as to power consumption Cross Allowable Cable Voltage drops per 30 meters of cable Ammeter Measuring and Checking ProceduresMeasuring Instruments VoltmeterTachometer Circuit TesterMeager Tester Dr.RobinPartNumber388-47565-08 SpecificationsModel DC Output Measuring AC Output MeasuringControl Panel Measuring Insulation ResistanceStator RG2800i RG3200i RG4300i RG2800iS RG3200iS RG4300iS Output Wires4P Connector Checking Functional MembersAC Receptacles Diode RectifierChecking table for analogue circuit tester Checking table for degital circuit testerFloat Type OIL Sensor DC Circuit BreakerPart Number Part Name Shape Usage Disassembly and AssemblyPreparation and Precautions Special ToolsStarter Handle Disassembly ProceduresFuel PIPES, Fuel Strainer and Battery Cables Side Cover L and RControl Panel and Inverter Unit Grounding WireChoke Wire For electric start modelsRear Cover Wire BandFuel Tank and Fuel System Parts Fuel TankAutothrottle Coupler Wire HarnessInverter Unit Components Control BOX and Inverter UnitComponents and Control BOX Components Control Panel Control BOX Components RG2800i / RG3200i / RG2800iSControl BOX Components RG4300i / RG3200iS / RG4300iS Muffler Foam Rubber InsulatorsMuffler Cover AIR Cleaner and Carburetor Soundproof Type Engine BlockOpen Frame Type Through Bolt and Rotor Alternator Components Bottom Extension Plate Blower HousingRecoil Starter Flywheel Drive Shaft and FANFor SOUND-PROOF Models Reassembly ProceduresMount Rubbers Sound InsulatorTightening torque 40-60 Kgf ・cm 4.4 Ft ・lbs Blower HousingFlywheel FAN and Drive Shaft Tightening torque 8.0-10.0 N・m 80-100 kgf・cm 5.9-7.4 ft・lbsThrough Bolt thread in reverse direction Recoil StarterTightening torque 6.5-8.5 N・m 65-85 kgf・cm 6.3 ft・lbs Rear CoverInstallation of Engine Alternator Assembly Onto Frame Tightening torque 6.0-8.0 N・m 60-80 kgf・cm 5.9 ft・lbs AIR Cleaner BaseAIR Cleaner Element CarburetorMuffler Cover MufflerControl BOX and Inverter Unit Grounding WiresConnection of Wiring Harness Tightening torque 4.0-6.0 N・m 40-60 kgf・cm 4.4 ft・lbs Clamping of the Choke Cable and Ground WiresAuto Throttle Fuel TankMuffler Cover Rear Rear Cover UpperGround Wire Side Cover Recoil Starter HandleRecoil Starter Disassembly proceduresDisassembly is completed Assembly procedure Five turns in counter-clockwise When Checking items after assemblyNo output power or Low output Trouble ShootingImproper revolutions Electronic throttle Engine does not start Start failure RG2800i / RG3200i / RG2800iS 50Hz-230V Recoil starter model Wiring DiagramRelay AC receptacle Earth ground terminal RG2800i / RG3200i / RG2800iS 50Hz-240V Recoil starter modelEngine 240V Switch Fuse10A RG2800i / RG3200i / RG2800iS 60Hz-120V Recoil starter model Engine 120V SwitchDiode DC output Terminal Rectifier Coil Page Lively Blvd. Wood Dale, IL 60191 Phone 630-350-8200 Fax
Related manuals