Craftsman 919.670070, MGP-670070 owner manual Operation, Know Your Generator, Not shown

Page 13

OPERATION

KNOW YOUR GENERATOR

Read this Owner’s Manual and Safety Rules before operation of your Generator. Compare this illustra- tion with your generator to familiarize yourself with the location of various controls and adjustments. Save the manual for future references.

FUEL TANK

CIRCUIT FUEL CAP

BREAKERS

120 VOLT GFCI

FUEL SHUT

OFF VALVE

RECEPTACLE

(not shown)

 

CHOKE

 

CONTROL

120 VOLT 3-PRONG

 

TWISTLOCK

MUFFLER

RECEPTACLE

 

240 VOLT 4-PRONG

 

TWISTLOCK

 

RECEPTACLE

 

ON/RUN/START

 

SWITCH

 

FUEL TANK- Capacity of 7 US gallons/26.5 Liters. CHOKE CONTROL- Used to start cold engine.

ENGINE OFF/RUN/START SWITCH- Used to start and stop engine.

FUEL VALVE LEVER (located on engine) - Used to shut off the flow of fuel to the engine.

ENGINE OIL FILL- Check and fill engine with oil.

AIR CLEANER- Includes filter element cartridge and foam pre-cleaner that limits the amount of dirt that enters the engine.

CIRCUIT BREAKER- Each receptacle has a circuit breaker to protect the generator from overloading.

GFCI (Ground Fault Circuit Interrupter) 120 VOLT RECEPTACLE- GFCI receptacles reduce the chance of electrical shock by tripping it's built in circuit breaker when it senses an imbalance in current. This receptacle is protected by 30 amp circuit breaker.

3- PRONG 120 VOLT RECEPTACLE- Used to supply 3500 watts of electrical power and is protected by 30 amp circuit breaker.

4-PRONG 240 VOLT TWISTLOCK RECEPTACLE - Used to supply 7000 watts of electrical power and is protected by 30 amp circuit breaker.

13 — ENG

MGP-670070

Image 13 Contents
Generator Owners ManualSold by Sears Canada, Inc., Toronto, Ont. M5B2B8 Table of Contents Important Safety Instructions Safety Guidelines DefinitionsHazard What could Happen HOW to Prevent IT Risk of Electrocution and FireRisk of Electrocution and Fire cont’d Or wall. do not Operate Unit Risk of FireIndoors or in ANY CON Fined AreaRead and Understand ALL Warnings Before Risk of Breathing Inhalation HazardRisk of Unsafe Operation Protector will void the warrantyL. listed voltage surge On your generatorRisk of Moving Parts Risk of HOT SurfacesRisk from Lifting Carton Contents AssemblyRemove Generator from Carton Tools Needed for AssemblyNegative Battery Cable Connection Star Washer Installation of BatteryGrounding the Generator Nut SolenoidInstalling Wheel KIT Know Your Generator OperationNot shown LOW OIL Shutdown ReceptaclesGenerator Capacity Obtaining Electricity from GeneratorBefore Starting Engine Connecting Generator To Main Electrical SupplyAdding Engine Oil GasolineStopping Engine To Start Your GeneratorFor recoil start Connecting Electrical Loads MaintenanceMaintenance Task Customer Responsibilities TableEngine Maintenance Generator MaintenanceGeneral Recommendations Air Cleaner Clean and Replace Spark PlugClean Cooling System Replace Fuel In-Line FilterStorage Service AdjustmentsCarburetor GovernorProblem Cause Correction Troubleshooting GuideEmissions Control Systems Statement Owner’s Warranty ResponsibilitiesENG ENG ENG Service and Repair Parts Vendu par Sears Canada, Inc., Toronto, Ont. M5B 2B8 Génératrice DEResponsabilités DU Client Entente D’ENTRETIENConserver CES Directives Risques Délectrocution ET D’INCENDIERisques Prévention Rieur OU Dans UN Endroit Clos Risques D’INCENDIERisques AUX Voies Respiratoires ET Risques D’INHALATION Les moteurs à essence produisent Génératrice Risques D’UNE Utilisation DangereuseRisques Reliés AUX Pièces Mobiles Risques Reliés AUX Surfaces ChaudesRisques Lors DU Levage Sac à pièces Contenu DE L’EMBALLAGEPièces et boîte à pièces pour l’ensemble de roues Sac à pièces pour la pose de la batterieRetrait DE LA Génératrice DE SON Emballage Outils Requis Pour L’ASSEMBLAGEMise À LA Terre DE LA Génératrice Pose Typique D’UNE BatterieÉcrou Solénoï de Support du Moteur Pose DE L’ENSEMBLE DE RouesBien Connaître Votre Génératrice FonctionnementDispositif D’ARRÊT Suite À UN Niveau BAS D’HUILE PrisesCapacité DE LA Génératrice Comment Obtenir DE L’ÉLECTRICITÉ DE LA GénératriceEssence Remplissage d’huile moteur Avant DE Démarrer LE MoteurArrêt du moteur Démarrage du moteurDémarrage électrique Démarrage à rappelTableau DES Responsabilités DU Client EntretienBranchement DE Charges Électriques Tâche D’ENTRETIENEntretien DE LA Génératrice Recommandations GénéralesEntretien DU Moteur HuileRemplacement du filtre à carburant en ligne Nettoyage et remplacement de la bougie dallumageFiltre à air Nettoyage du système de refroidissementEntreposage Réglages D’ENTRETIENDirectives Pour L’ENTREPOSAGE Problème Cause Correction Guide DE DépannageResponsabilités de garantie du propriétaire Remarque Remarque Remarque Entretien ET Pieces DE Rechange