Briggs & Stratton 030235-01 manual No Charge, Claims and Coverage Exclusions

Page 23

3.No Charge

Repair or replacement of any Warranted Part will be performed at no charge to the owner, including diagnostic labor which leads to the determination that a Warranted Part is defective, if the diagnostic work is performed at an Authorized B&S Service Dealer. For emissions warranty service contact your nearest Authorized B&S Service Dealer as listed in the telephone directory under “Engines, Gasoline,” “Gasoline Engines,” “Lawn Mowers,” or similar category.

4.Claims and Coverage Exclusions

Warranty claims shall be filed in accordance with the provisions of the B&S Engine Warranty Policy. Warranty coverage shall be excluded for failures of Warranted Parts which are not original B&S parts or because of abuse, neglect or improper maintenance as set forth in the B&S Engine Warranty Policy. B&S is not liable to cover failures of Warranted Parts caused by the use of add–on, non–original, or modified parts.

5.Maintenance

Any Warranted Part which is not scheduled for replacement as required maintenance or which is scheduled only for regular inspection to the effect of “repair or replace as necessary” shall be warranted as to defects for the warranty period. Any Warranted Part which is scheduled for replacement as required maintenance shall be warranted as to defects only for the period of time up to the first scheduled replacement for that part. Any replacement part that is equivalent in performance and durability may be used in the performance of any maintenance or repairs. The owner is responsible for the performance of all required maintenance, as defined in the B&S Owner’s Manual.

6.Consequential Coverage

Coverage hereunder shall extend to the failure of any engine components caused by the failure of any Warranted Part still under warranty.

Emissions Durability Period and Air Index

Information On Your Engine Emissions

Label

Engines that are certified to meet the California Air Resources Board (CARB) Tier 2 Emission Standards must display information regarding the Emissions Durability Period and Air Index. The engine manufacturer makes this information available to the consumer on emission labels.

The Emissions Durability Period describes the number of hours of actual running time for which the engine is certified to be emissions compliant, assuming proper maintenance in accordance with the Maintenance Schedule. The following categories are used:

Moderate: Engine is certified to be emission compliant for 125 hours of actual engine running time.

Intermediate: Engine is certified to be emission compliant for 250 hours of actual engine running time.

Extended: Engine is certified to be emission compliant for 500 hours of actual engine running time.

For example, a typical walk-behind lawn mower is used 20 to 25 hours per year. Therefore, the Emissions Durability Period of an engine with an intermediate rating would equate to 10 to 12 years.

The Air Index is a calculated number describing the relative level of emissions for a specific engine family. The lower the Air Index, the cleaner the engine. This information is displayed in graphical form on the emissions label.

Emissions Compliance Period On Engine Emissions Compliance Label

After July 1, 2000 certain Briggs & Stratton engines will be certified to meet the United States Environmental Protection Agency (USEPA) Phase 2 emission standards. For phase 2 certified engines, the Emissions Compliance Period referred to on the Emissions Compliance label indicates the number of operating hours for which the engine has been shown to meet Federal emission requirements. For engines less than 225 cc displacement, Category C = 125 hours, B = 250 hours and A = 500 hours. For engines of 225 cc or more, Category C = 250 hours, B = 500 hours and A = 1000 hours.

This generator engine has an intermediate rating with an Air Index of 3. The EPA Emissions compliance period is Category C. The displacement of this engine is 305 cc.

Below is a generic representation of the emission label typically found on a certified engine.

21

Image 23 Contents
Watts Revision Serial Number Engine Model Number Date Purchased Where to Find UsTable of Contents Hazard Symbols and Meanings Safety RulesWhen transporting or repairing equipment When adding or draining fuelWhen starting equipment When operating equipmentEquipment Description AssemblyShipment Contents Install Wheel KitType of Fuel When adding fuelVerify Engine Oil Level Add FuelSpecial Requirements Connecting to a Building’s Electrical SystemSystem Ground Generator Location120/240 Volt AC, 30 Amp Locking Receptacle Features and ControlsVolt AC, 20 Amp, Duplex Receptacles ReceptaclesGenerator Adapter Cord Set 120/240 Volt AC, 30 Amp, Locking ReceptacleStarting the Engine OperationStopping the Engine Connecting Electrical LoadsExample Power ManagementDon’t Overload Generator CapacityEmissions Control MaintenanceMaintenance Schedule General RecommendationsOil Recommendations Generator MaintenanceCleaning OilChanging Engine Oil Checking Oil LevelAdding Engine Oil Clean Spark Arrester Screen Service Air CleanerService Spark Plug Check Valve Clearance Carburetor AdjustmentClean and inspect the spark arrester as follows Engine Air Cooling System Storage Troubleshooting Engine Technical Information SpecificationsReplacement Parts Maintenance ItemsLength of Coverage Owner’s Warranty ResponsibilitiesWarranted Parts Claims and Coverage Exclusions Maintenance Consequential CoverageNo Charge Warranty Period This page reserved Dónde encontrarnos Operando Resolución de problemas Especificaciones GarantíasMontaje Controles y característicasSímbolos de peligro y sus significados Normas de seguridadCuando transporte o repare el equipo Cuando anada combustible o vacíe el depósitoCuando ponga en funcionamiento el equipo Cuando opere el equipoContenido de la caja MontajeDescripción del equipo Desembalaje del generadorTipo de gasolina Comprobar el nivel de aceite del motorAgregue combustible Cuando anada combustibleRequisitos Especiales Tierra del sistemaConexión al sistema eléctrico de un edificio Ubicación del generadorControles y características del generador Juego de cables del adaptador del generador Tomas eléctricasTomas eléctricas dobles de 120 V CA y 20 a Dispositivo de seguridad de 120/240 V, 30 aEncienda el motor OperandoParada del motor Conexión de cargas eléctricasControl de la energía No sobrecargar el generadorCapacidad EjemploControl de emisiones MantenimientoPlan de mantenimiento Recomendaciones GeneralesRecomendaciones sobre el aceite Mantenimiento del GeneradorLimpieza AceiteCambio de Aceite del Motor Comprobación del Nivel de AceiteAdición de Aceite del Motor Limpie la Pantalla Apagachispas Servicio del depurador de aireServicio del bujía Limpie e inspeccione el apagachispas de la siguiente manera Sistema de refrigeración de aireComprobación de holgura de la válvula Ajuste del CarburadorAlmacenamiento Problemo Causa Accion Resolución de problemasInformación técnica sobre el motor Duración de la cobertura Responsabilidades de la garantía del propietarioPiezas garantizadas Cobertura de daños derivados Servicio gratuitoSolicitudes y exclusiones de cobertura MantenimientoPeríodo DE Garantía