Briggs & Stratton 030235-01 Verify Engine Oil Level, Add Fuel, When adding fuel, Type of Fuel

Page 7

5.Install e-ring with pliers, squeezing from top of e-ring to bottom of axle.

6.Repeat steps 4 and 5 to secure second wheel.

7.Tip generator so that engine side is down.

8.Line up holes in support leg (E) with holes in generator frame.

9.Attach support leg using 2 capscrews (M8 x 16 mm) (F) and 2 hex nuts (G). Tighten with a 13 mm socket wrench and 13 mm wrench.

10.Return generator to normal operating position (resting on wheels and support leg).

Verify Engine Oil Level

The generator engine is shipped from the factory filled with oil (API SJ or higher 10W-30). This allows for generator operation in the widest range of temperature and climate conditions. Before starting the engine, check oil level and ensure that engine is serviced as described in Maintenance.

CAUTION

Any attempt to crank or start the engine without verifying it has been properly serviced with the recommended oil will result in equipment failure.

Refer to Maintenance for oil fill information.

Damage to equipment resulting from failure to follow this instruction will void warranty.

NOTE: See Oil in the Maintenance section to review oil recomendations. Verify provided oil in engine is the correct viscosity for current ambient temperature.

Add Fuel

All fuel is not the same. If a starting or performance problem is encountered immediately after new fuel has been used, try another service station or change brands.

NOTE: This engine is certified to operate on gasoline.

Exhaust Emissions Control System: EM (Engine Modifications).

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

When adding fuel:

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill or drain fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

If fuel spills, wait until it evaporates before starting engine.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

Type of Fuel

1.Always use clean, fresh, unleaded gasoline with a minimum of 87 octane/87 AKI (91 RON) with equipment. DO NOT mix oil with fuel. DO NOT modify the engine fuel system or carburetor to run on alternative fuels.

NOTE: Fuel with up to 10% ethanol (gasohol) or up to 15% MTBE (methyl tertiary butyl ether) is acceptable.

IMPORTANT: Use of any fuel other than those approved above will void warranty. Some areas require that fuel pumps be marked if the fuel contains alcohols or ethers. If you are not sure if your fuel contains alcohol or ethers that are different than those approved above, then check with the service station operator.

2.Clean area around fuel fill cap, remove cap.

3.Slowly add unleaded gasoline (A) to fuel tank (B). Be careful not to overfill. Allow at least 1.5" (38 mm) of tank space (C) for fuel expansion, as shown in Figure 2.

B

C

A

Figure 2 — Fuel Expansion

A - Fuel

B - Fuel Tank

C - Tank Space

4.Install fuel cap and let any spilled fuel evaporate before starting engine.

To avoid engine problems, the fuel system should be treated with a fuel preserver or emptied before storage of 30 days or longer. To protect the fuel system from gum formation, use Briggs & Stratton FRESH START™ fuel stabilizer plus. If fuel preserver is not used, drain the fuel tank, start the engine and let it run until the fuel lines and carburetor are empty. Use fresh fuel next season. See Storage in the Maintenance section for additional information.

NEVER use engine or carburetor cleaner products in the fuel tank as permanent damage may occur.

High-altitude use

Operation at high altitudes (over 5,000 feet [1524 m]), may require a high-altitude carburetor jet kit to improve performance and decrease fuel consumption. See your local authorized Briggs & Stratton dealer for more information.

5

Image 7
Contents Watts Revision Serial Number Engine Model Number Date Purchased Where to Find UsTable of Contents Hazard Symbols and Meanings Safety RulesWhen transporting or repairing equipment When adding or draining fuelWhen starting equipment When operating equipmentEquipment Description AssemblyShipment Contents Install Wheel KitType of Fuel When adding fuelVerify Engine Oil Level Add FuelSpecial Requirements Connecting to a Building’s Electrical SystemSystem Ground Generator Location120/240 Volt AC, 30 Amp Locking Receptacle Features and ControlsVolt AC, 20 Amp, Duplex Receptacles ReceptaclesGenerator Adapter Cord Set 120/240 Volt AC, 30 Amp, Locking ReceptacleStarting the Engine OperationStopping the Engine Connecting Electrical LoadsExample Power ManagementDon’t Overload Generator CapacityEmissions Control MaintenanceMaintenance Schedule General RecommendationsOil Recommendations Generator MaintenanceCleaning OilAdding Engine Oil Checking Oil LevelChanging Engine Oil Service Spark Plug Service Air CleanerClean Spark Arrester Screen Check Valve Clearance Carburetor AdjustmentClean and inspect the spark arrester as follows Engine Air Cooling SystemStorage Troubleshooting Engine Technical Information SpecificationsReplacement Parts Maintenance ItemsWarranted Parts Owner’s Warranty ResponsibilitiesLength of Coverage No Charge Maintenance Consequential CoverageClaims and Coverage Exclusions Warranty Period This page reserved Dónde encontrarnos Operando Resolución de problemas Especificaciones GarantíasMontaje Controles y característicasSímbolos de peligro y sus significados Normas de seguridadCuando transporte o repare el equipo Cuando anada combustible o vacíe el depósitoCuando ponga en funcionamiento el equipo Cuando opere el equipoContenido de la caja MontajeDescripción del equipo Desembalaje del generadorTipo de gasolina Comprobar el nivel de aceite del motorAgregue combustible Cuando anada combustibleRequisitos Especiales Tierra del sistemaConexión al sistema eléctrico de un edificio Ubicación del generadorControles y características del generador Juego de cables del adaptador del generador Tomas eléctricasTomas eléctricas dobles de 120 V CA y 20 a Dispositivo de seguridad de 120/240 V, 30 aEncienda el motor OperandoParada del motor Conexión de cargas eléctricasControl de la energía No sobrecargar el generadorCapacidad EjemploControl de emisiones MantenimientoPlan de mantenimiento Recomendaciones GeneralesRecomendaciones sobre el aceite Mantenimiento del GeneradorLimpieza AceiteAdición de Aceite del Motor Comprobación del Nivel de AceiteCambio de Aceite del Motor Servicio del bujía Servicio del depurador de aireLimpie la Pantalla Apagachispas Limpie e inspeccione el apagachispas de la siguiente manera Sistema de refrigeración de aireComprobación de holgura de la válvula Ajuste del CarburadorAlmacenamiento Problemo Causa Accion Resolución de problemasInformación técnica sobre el motor Piezas garantizadas Responsabilidades de la garantía del propietarioDuración de la cobertura Cobertura de daños derivados Servicio gratuitoSolicitudes y exclusiones de cobertura MantenimientoPeríodo DE Garantía

030235-01 specifications

The Briggs & Stratton 030235-01 is a key component in the realm of outdoor power equipment, renowned for its reliability and performance. This model is primarily designed for use in portable generators, offering a powerful and efficient engine that meets the demands of users looking for dependable energy solutions.

One of the standout features of the 030235-01 is its impressive engine output. With a robust design, it provides a reliable source of power for various applications, whether for home backup during outages or for job sites requiring portable energy. This model is built with a reliable four-stroke engine, allowing for smooth operation and reduced emissions compared to two-stroke engines. This makes it an environmentally friendly option for those needing outdoor power.

The motor is equipped with advanced technologies that enhance its performance. The overhead valve (OHV) design optimizes engine efficiency while maintaining low operating temperatures, ensuring longer life and reduced wear. Additionally, the engine features a splash lubrication system, taking care of critical components to minimize friction and ensure a smooth operation even under heavy loads.

Another key characteristic of the Briggs & Stratton 030235-01 is its easy-starting capability. Many users appreciate this feature, especially during emergencies when time is of the essence. The primer bulb and choke system facilitate a hassle-free startup, allowing users to get the engine running with minimal effort.

Durability is also a key focus of this engine's design. Constructed with high-quality materials and comprehensive engineering, the 030235-01 can withstand the rigors of frequent use. It has a sturdy build that resists corrosion, making it suitable for various outdoor conditions. Coupled with routine maintenance, this generator can serve users for years to come.

On the ease of use front, the Briggs & Stratton 030235-01 is designed for straightforward operation. It has an intuitive control panel that enables users to manage their power needs without any confusion, enhancing the overall user experience.

In summary, the Briggs & Stratton 030235-01 stands out for its powerful engine output, innovative technologies such as OHV design and splash lubrication, durability under various conditions, and user-friendly operation. This combination makes it a preferred choice for those seeking reliable portable power solutions.