Problem | Cause | Correction | |||
|
|
|
|
| |
| 1. | One of the circuit breakers is | 1. | Reset circuit breaker. | |
|
| open. |
|
| |
No AC output is available, but | 2. | Fault in generator. | 2. | Contact Authorized service facility. | |
3. | Poor connection or defective cord | 3. | Check and repair. | ||
generator is running. | |||||
| set. |
|
| ||
|
|
|
| ||
| 4. | Connected device is bad. | 4. | Connect another device that is in | |
|
|
|
| good condition. | |
|
|
|
|
| |
Generator runs good at | 1. | Short circuit in a connected load. | 1. | Disconnect shorted electrical load. | |
|
|
|
| ||
but "bogs" down" when loads are | 2. | Generator is overloaded. | 2. | See "Don't Overload Generator". | |
connected. | 3. | Shorted generator circuit. | 3. | Contact Authorized service facility. | |
| |||||
|
|
|
|
| |
| 1. | 10 Amp | 1. | Replace fuse. | |
Generator will not start; or starts | 2. | Discharged battery. | 2. | Jump start generator and/or charge | |
and runs rough. |
|
|
| battery. | |
| 3. | Failed battery. | 3. | Replace battery. | |
|
|
| |||
Generator shuts down during | Out of gasoline. | Fill fuel tank. | |||
operation. |
|
|
|
| |
|
|
| |||
Generator lacks power. | Load is too high. | See "Don't Overload Generator". | |||
|
|
|
|
|