Briggs & Stratton 206494GS manual Maintenance Schedule, Generator Maintenance

Page 15

Maintenance

Maintenance Schedule

Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions noted below.

First 5 Hours

• Change engine oil

Every 8 Hours or Daily

Clean debris

Check engine oil level

Every 25 Hours or Yearly

• Service engine air cleaner1

Every 50 Hours or Yearly

• Change engine oil1

Every 100 Hours or Yearly

Service spark plug

Service spark arrester

Clean cooling system1

Every 250 Hours or Yearly

• Check valve clearance

1 Service more often under dirty or dusty conditions.

General Recommendations

Regular maintenance will improve the performance and extend the life of the generator. See any authorized dealer for service.

The generator’s warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.

Some adjustments will need to be made periodically to properly maintain your generator.

All service and adjustments should be made at least once each season. Follow the requirements in the Maintenance Schedule chart above.

NOTE: Once a year you should clean or replace the spark plug and replace the air filter. A new spark plug and clean air filter assure proper fuel-air mixture and help your engine run better and last longer.

Emissions Control

Maintenance, replacement, or repair of the emissions control devices and systems may be performed by any non-road engine repair establishment or individual.

However, to obtain ”no charge” emissions control service, the work must be performed by a factory authorized dealer. See the Emissions Warranty.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture, or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material.

NOTE: DO NOT use water or other liquids to clean generator. Liquids can enter engine fuel system, causing poor performance and/or failure to occur. In addition, if liquid enters generator through cooling air slots, some of the liquid will be retained in voids and cracks of the rotor and stator winding insulation. Liquid and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

Cleaning

Daily or before use, look around and underneath the generator for signs of oil or fuel leaks. Clean accumulated debris from inside and outside the generator. Keep the linkage, spring and other engine controls clean. Keep the area around and behind the muffler free from any combustible debris. Inspect cooling air slots and openings on generator. These openings must be kept clean and unobstructed.

Engine parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris:

• Use a damp cloth to wipe exterior surfaces clean.

NOTICE

Improper treatment of generator can damage it and shorten its life.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

Use a soft bristle brush to loosen caked on dirt or oil.

Use a vacuum cleaner to pick up loose dirt and debris.

15

Image 15
Contents Operator’s Manual Date Purchased Where to Find UsGenerator EngineTable of Contents Hazard Symbols and Meanings Operator SafetySafety Rules Safety alert symbol is used with a signal wordBroken bones, fractures, bruises, or sprains could result Engine exhaust from this product containsContact with muffler area can result in serious burns When Adjusting or Making Repairs to Your GeneratorWhen Testing for Engine Spark Generator produces hazardous voltageUnpack Generator AssemblyShipment Contents Install Wheel KitHigh Altitude Clean area around fuel fill cap, remove capAdd Fuel Fuel must meet these requirementsSpecial Requirements Connecting to a Building’s Electrical SystemSystem Ground Generator LocationFeatures and Controls Volt AC, 20 Amp, Duplex Receptacles Cord Sets and ReceptaclesNema L14-30 120/240 Volt AC, 30 Amp, Locking ReceptacleStarting the Engine OperationConnecting Electrical Loads Stopping the EngineMove fuel valve to Off position Wattage Reference Guide Don’t Overload GeneratorMaintenance Maintenance ScheduleGenerator Maintenance Adding Engine Oil Engine MaintenanceOil Recommendations Checking Oil LevelClean and inspect the spark arrester as follows Service Air CleanerService Spark Plug Service Spark ArresterClean Cooling System Carburetor AdjustmentCheck Valve Clearance Storage Troubleshooting Emissions Control System Warranty Owner’s Warranty ResponsibilitiesWarranties Maintenance Emission InformationClaims and Coverage Exclusions Limited Warranty 800 Product SpecificationsCommon Service Parts AC Load CurrentManual del Operario Fecha de compra Dónde encontrarnosGenerador MotorControles y características Resolución de problemas GarantíasSeguridad de operario MontajeSímbolos de peligro y sus significados Seguridad de operarioDescripción del equipo Reglas de seguridadPeligro Precaución Instale el juego de ruedas MontajeDesembalaje del generador Contenido de la cajaAgregue combustible El combustible debe reunir los siguientes requisitosGran altitud Requisitos especiales Tierra del sistemaConexión al sistema eléctrico de un edificio Ubicación del generadorDel motor y está equipado con una pantalla apagachispas Controles y característicasJuegos de cordones y enchufes conectores Dispositivo de seguridad de 120/240 V, 30 aToma eléctricas dobles de 120 V CA y 20 a Encienda el motor OperandoGire la válvula de combustible blanca hasta la posición Off Conexión de cargas eléctricasParada del motor El motor podría petardear, incendiarse o dañarseControl de la energía No sobrecargar el generadorCapacidad EjemploControl de emisiones MantenimientoPlan de mantenimiento Recomendaciones generalesAdición de aceite del motor Mantenimiento del motorAceite Recomendaciones sobre el aceite Comprobación del nivel de aceiteServicio del depurador de aire Servicio del bujíaLimpie la pantalla apagachispas Ajuste del carburador Limpie e inspeccione el apagachispas de la siguiente maneraSistema de refrigeración de aire Comprobación de holgura de la válvulaAlmacenamiento Problemo Causa Accion Resolución de problemasOperaciones de mantenimiento que se enumeran en las GarantíasGarantía del sistema de control de emisiones Responsabilidades de la garantía del propietarioInformación sobre emisiones Garantía Limitada Especificaciones del producto Servicio común despideCorriente Carga de C.A