Assembly

Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended oil and fuel.

If you have any problems with the assembly of your generator, please call the generator helpline at 1-800-743-4115. If calling for assistance, please have the model, revision, and serial number from the identification label available. See Generator Controls and Features for identification label location.

Unpack Generator

1.Set the carton on a rigid, flat surface.

2.Remove everything from carton except generator.

3.Open carton completely by cutting each corner from top to bottom.

4.Leave generator on carton to install wheel kit.

Shipment Contents

The generator is supplied with:

Operator’s manual

Wheel kit

Product registration card

Install Wheel Kit

NOTE: Wheel kit is not intended for over-the-road use.

You will need the following tools to install these components:

13 mm wrench

Socket wrench with a 13 mm socket

Pliers

Safety glasses

Install the wheel kit as follows:

1.Tip generator so that engine end is up.

2.Slide axle (A) through both mounting brackets.

B

A

C

FA

E BD G

3.Place a wheel (B) on each side as shown below.

4.Place a washer (C) on axle and then place an e-ring (D) in axle groove.

CAUTION

E-rings can cause eye injury.

E-rings can spring back and become airborne when installing or removing.

Always wear eye protection when installing/removing e-rings.

5.Install e-ring with pliers, squeezing from top of e-ring to bottom of axle.

6.Repeat steps 4 and 5 to secure second wheel.

7.Tip generator so that engine side is down.

8.Line up holes in support leg (E) with holes in generator frame.

9.Attach support leg using two short capscrews (M8 x 16 mm) (F) and two locking hex nuts (G). Tighten with a 13 mm socket and wrench.

10.Return generator to normal operating position (resting on wheels and support leg).

Verify Engine Oil Level

The generator engine is shipped from the factory filled with oil (API SJ or higher 10W-30). This allows for generator operation in the widest range of temperature and climate conditions. Before starting the engine, check oil level and ensure that engine is serviced as described in Maintenance.

NOTE: See Oil in the Maintenance section to review oil recomendations. Verify provided oil in engine is the correct viscosity for current ambient temperature.

NOTICE

Any attempt to crank or start the engine before it has been properly filled with the recommended oil will result in equipment failure.

Refer to Maintenance for oil fill information.

Damage to equipment resulting from failure to follow this instruction will void warranty.

7

Image 7
Contents Operator’s Manual Date Purchased Where to Find UsGenerator EngineTable of Contents Hazard Symbols and Meanings Operator SafetySafety Rules Safety alert symbol is used with a signal wordBroken bones, fractures, bruises, or sprains could result Engine exhaust from this product containsContact with muffler area can result in serious burns When Adjusting or Making Repairs to Your GeneratorWhen Testing for Engine Spark Generator produces hazardous voltageUnpack Generator AssemblyShipment Contents Install Wheel KitHigh Altitude Clean area around fuel fill cap, remove capAdd Fuel Fuel must meet these requirementsSpecial Requirements Connecting to a Building’s Electrical SystemSystem Ground Generator LocationFeatures and Controls Volt AC, 20 Amp, Duplex Receptacles Cord Sets and ReceptaclesNema L14-30 120/240 Volt AC, 30 Amp, Locking ReceptacleStarting the Engine OperationStopping the Engine Connecting Electrical LoadsMove fuel valve to Off position Wattage Reference Guide Don’t Overload GeneratorMaintenance Schedule MaintenanceGenerator Maintenance Adding Engine Oil Engine MaintenanceOil Recommendations Checking Oil LevelClean and inspect the spark arrester as follows Service Air CleanerService Spark Plug Service Spark ArresterCarburetor Adjustment Clean Cooling SystemCheck Valve Clearance Storage Troubleshooting Owner’s Warranty Responsibilities Emissions Control System WarrantyWarranties Emission Information MaintenanceClaims and Coverage Exclusions Limited Warranty 800 Product SpecificationsCommon Service Parts AC Load CurrentManual del Operario Fecha de compra Dónde encontrarnosGenerador MotorControles y características Resolución de problemas GarantíasSeguridad de operario MontajeSímbolos de peligro y sus significados Seguridad de operarioDescripción del equipo Reglas de seguridadPeligro Precaución Instale el juego de ruedas MontajeDesembalaje del generador Contenido de la cajaEl combustible debe reunir los siguientes requisitos Agregue combustibleGran altitud Requisitos especiales Tierra del sistemaConexión al sistema eléctrico de un edificio Ubicación del generadorDel motor y está equipado con una pantalla apagachispas Controles y característicasDispositivo de seguridad de 120/240 V, 30 a Juegos de cordones y enchufes conectoresToma eléctricas dobles de 120 V CA y 20 a Encienda el motor OperandoGire la válvula de combustible blanca hasta la posición Off Conexión de cargas eléctricasParada del motor El motor podría petardear, incendiarse o dañarseControl de la energía No sobrecargar el generadorCapacidad EjemploControl de emisiones MantenimientoPlan de mantenimiento Recomendaciones generalesAdición de aceite del motor Mantenimiento del motorAceite Recomendaciones sobre el aceite Comprobación del nivel de aceiteServicio del bujía Servicio del depurador de aireLimpie la pantalla apagachispas Ajuste del carburador Limpie e inspeccione el apagachispas de la siguiente maneraSistema de refrigeración de aire Comprobación de holgura de la válvulaAlmacenamiento Problemo Causa Accion Resolución de problemasOperaciones de mantenimiento que se enumeran en las GarantíasGarantía del sistema de control de emisiones Responsabilidades de la garantía del propietarioInformación sobre emisiones Garantía Limitada Servicio común despide Especificaciones del productoCorriente Carga de C.A