Status Read Command
Format
The command is sent from PC to the projector with the format below;
‘CR’ [Command] ‘CR’
Command: one character (refer to the command table below.
■The projector decodes the command and returns the ‘Character string’ with the format below;
Note
The tables on pages 56~58 show the typical command lists for con- trolling the projector. Please consult your local dealer for further information of other commands.
Command | Function | Projector | Projector status | |
Return | ||||
|
|
| ||
|
|
|
| |
|
| 00 | Power ON | |
|
| 80 | Standby mode | |
|
|
|
| |
|
| 20 | Cooling Down | |
|
|
|
| |
|
| 10 | Power Failure | |
CR0 | Status Read | 28 | Cooling Down due to Abnormal Temperature | |
|
| in process | ||
|
|
| ||
|
| 21 | Cooling Down in process after Off due to lamp | |
|
| failure | ||
|
|
| ||
|
| 81 | Standby after Cooling Down due to lamp | |
|
| failure | ||
|
|
| ||
CR1 | Input Mode Read |
|
| |
|
|
|
| |
CR3 | Lamp Time Read |
|
| |
|
|
|
| |
CR4 | Setting Read |
|
| |
|
|
| S1 = Temperature at Sensor 1 (˚C) | |
CR6 | Temperature Read | S1 | (ex.) S1 = 12.3˚C | |
|
|
| ||
CR7 | Lamp Mode Read |
|
|
58