Fujitsu MPG3XXXAH manual Command block registers

Models: MPG3XXXAH

1 195
Download 195 pages 62.57 Kb
Page 75
Image 75

5.2.2Command block registers

(1)Data register (X'1F0')

The Data register is a 16-bit register for data block transfer between the device and the host system. Data transfer mode is PIO or LBA mode.

(2)Error register (X'1F1')

The Error register indicates the status of the command executed by the device. The contents of this register are valid when the ERR bit of the Status register is 1.

This register contains a diagnostic code after power is turned on, a reset, or the EXECUTIVE DEVICE DIAGNOSTIC command is executed.

[Status at the completion of command execution other than diagnostic command]

Bit 7

 

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

 

 

 

 

 

 

 

 

 

ICRC

 

UNC

X

IDNF

X

ABRT

TK0NF

AMNF

 

 

 

 

 

 

 

 

 

X: Unused

 

 

 

 

 

 

 

-Bit 7: Interface CRC error (ICRC). This bit indicates that an interface CRC error has occurred during an Ultra DMA data transfer. The content of this bit is not applicable for Multiword DMA transfers.

-Bit 6: Uncorrectable Data Error (UNC). This bit indicates that an uncorrectable data error has been encountered.

- Bit 5:

Unused

-Bit 4: ID Not Found (IDNF). This bit indicates an error except for, uncorrectable error and SB not found, and Aborted Command.

- Bit 3:

Unused

-Bit 2: Aborted Command (ABRT). This bit indicates that the requested command was aborted due to a device status error (e.g. Not Ready, Write Fault) or the command code was invalid.

-Bit 1: Track 0 Not Found (TK0NF). This bit indicates that track 0 was not found during RECALIBRATE command execution.

-Bit 0: Address Mark Not Found. This bit indicates that an SB not found error has been encountered.

5 - 8

C141-E112-01EN

Page 75
Image 75
Fujitsu MPG3XXXAH manual Command block registers