Fujitsu MPG3XXXAH manual At command completion I/O registers contents to be read, 1F7 HST, 1F6 HDH

Models: MPG3XXXAH

1 195
Download 195 pages 62.57 Kb
Page 112
Image 112
(23)IDLE IMMEDIATE (X'95' or X'E1')

At command completion (I/O registers contents to be read)

1F7H(ST)

 

 

 

Status information

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

×

 

DV

 

xx

 

 

 

 

 

 

 

 

1F5H(CH)

 

 

 

 

xx

 

1F4H(CL)

 

 

 

 

xx

 

1F3H(SN)

 

 

 

 

xx

 

1F2H(SC)

 

 

 

 

xx

 

1F1H(ER)

 

 

 

Error information

 

 

 

 

 

 

 

 

 

(23)IDLE IMMEDIATE (X'95' or X'E1')

Upon receipt of this command, the device sets the BSY bit of the Status register, and enters the idle mode. Then, the device clears the BSY bit, and generates an interrupt. This command does not support the automatic power-down function.

At command issuance (I/O registers setting contents)

1F7H(CM)

 

 

 

X'95' or X'E1'

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

×

DV

 

xx

 

 

 

 

 

 

 

1F5H(CH)

 

 

 

xx

 

1F4H(CL)

 

 

 

xx

 

1F3H(SN)

 

 

 

xx

 

1F2H(SC)

 

 

 

xx

 

1F1H(FR)

 

 

 

xx

 

 

 

 

 

 

 

 

At command completion (I/O registers contents to be read)

1F7H(ST)

 

 

 

Status information

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

×

 

DV

 

xx

 

 

 

 

 

 

 

 

1F5H(CH)

 

 

 

 

xx

 

1F4H(CL)

 

 

 

 

xx

 

1F3H(SN)

 

 

 

 

xx

 

1F2H(SC)

 

 

 

 

xx

 

1F1H(ER)

 

 

 

Error information

 

 

 

 

 

 

 

 

 