Fujitsu MPG3XXXAH STANDBY X96 or XE2, At command issuance I/O registers setting contents, 1F7 HCM

Models: MPG3XXXAH

1 195
Download 195 pages 62.57 Kb
Page 113
Image 113
(24)STANDBY (X'96' or X'E2')

(24)STANDBY (X'96' or X'E2')

Upon receipt of this command, the device sets the BSY bit of the Status register and enters the standby mode. The device then clears the BSY bit and generates an interrupt. The device generates an interrupt even if the device has not fully entered the standby mode. If the device has already spun down, the spin-down sequence is not implemented.

If the contents of the Sector Count register is other than 0, the automatic power-down function is enabled and the timer starts countdown when the device returns to idle mode.

When the timer value reaches 0 (passed a specified time), the device enters the standby mode. If the contents of the Sector Count register is 0, the automatic power-down function is disabled.

Under the standby mode, the spindle motor is stopped. Thus, when the command involving a seek such as the READ SECTOR(s) command is received, the device processes the command after driving the spindle motor.

At command issuance (I/O registers setting contents)

1F7H(CM)

 

 

 

 

X'96' or X'E2'

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

×

 

DV

 

xx

 

 

 

 

 

 

 

 

1F5H(CH)

 

 

 

 

xx

 

1F4H(CL)

 

 

 

 

xx

 

1F3H(SN)

 

 

 

 

xx

 

1F2H(SC)

 

 

 

Period of timer

 

1F1H(FR)

 

 

 

 

xx

 

 

 

 

 

 

 

 

 

At command completion (I/O registers contents to be read)

1F7H(ST)

 

 

 

Status information

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

×

 

DV

 

xx

 

 

 

 

 

 

 

 

1F5H(CH)

 

 

 

 

xx

 

1F4H(CL)

 

 

 

 

xx

 

1F3H(SN)

 

 

 

 

xx

 

1F2H(SC)

 

 

 

 

xx

 

1F1H(ER)

 

 

 

Error information

 

 

 

 

 

 

 

 

 

(25)STANDBY IMMEDIATE (X'94' or X'E0')

Upon receipt of this command, the device sets the BSY bit of the Status register and enters the standby mode. The device then clears the BSY bit and generates an interrupt. This command does not support the automatic power-down sequence.

5 - 46

C141-E112-01EN

Page 113
Image 113
Fujitsu MPG3XXXAH manual STANDBY X96 or XE2, At command issuance I/O registers setting contents, 1F7 HCM, 1F6 HDH, 1F5 HCH