6.1.1Response to power-on

After the master device (device 0) releases its own power-on reset state, the master device shall check a DASP- signal for up to 450 ms to confirm presence of a slave device (device 1). The master device recognizes presence of the slave device when it confirms assertion of the DASP- signal. Then, the master device checks a PDIAG- signal to see if the slave device has successfully completed the power-on diagnostics.

If the master device cannot confirm assertion of the DASP- signal within 450 ms, the master device recognizes that no slave device is connected.

After the slave device (device 1) releases its own power-on reset state, the slave device shall report its presence and the result of power-on diagnostics to the master device as described below:

DASP- signal: Asserted within 400 ms, and negated after the first command is received from the host or within 31 seconds or after executing software reset, which ever comes first.

PDIAG- signal: Negated within 1 ms and asserted within 30 seconds, then negated within 31 seconds.

 

Power on

 

 

 

 

 

 

 

Master device

 

 

 

 

 

 

 

 

 

Power On Reset-

 

 

Status Reg.

 

 

BSY bit

Max. 31 sec.

 

 

 

 

 

 

 

 

 

 

 

Checks DASP- for up to

If presence of a slave device is

 

 

450 ms.

confirmed, PDIAG- is checked for

 

 

 

 

 

 

up to 31 seconds.

Slave device

Power On Reset-

BSY bit

Max. 1 ms.

PDIAG-

Max. 30 sec.

DASP-

Max. 400 ms.

Max. 31 sec.

Figure 6.1 Response to power-on

6 - 2

C141-E112-01EN

Page 173
Image 173
Fujitsu MPG3XXXAH manual Response to power-on