Fujitsu MPG3XXXAH Read Dma, Write Long, Security Disable Password, Read Long, Write Multiple

Models: MPG3XXXAH

1 195
Download 195 pages 62.57 Kb
Page 128
Image 128
READ VERIFY

READ DMA

WRITE LONG

SECURITY DISABLE PASSWORD

READ LONG

WRITE MULTIPLE

SECURITY FREEZE LOCK

READ MULTIPLE

WRITE SECTORS

SECURITY SET PASSWORD

READ SECTORS

WRITE VERIFY

FORMAT TRACK

READ VERIFY

SET MAX ADDRESS

FLASH CACHE

WRITE DMA

At command issuance (I-O registers setting contents)

1F7H(CM)

1

1

1

1

0

1

0

1

 

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

×

DV

 

 

 

xx

 

 

 

 

 

 

 

 

 

 

 

1F5H(CH)

 

 

 

 

xx

 

 

 

1F4H(CL)

 

 

 

 

xx

 

 

 

1F3H(SN)

 

 

 

 

xx

 

 

 

1F2H(SC)

 

 

 

 

xx

 

 

 

1F1H(FR)

 

 

 

 

xx

 

 

 

 

 

 

 

 

 

 

 

 

 

At command completion (I-O registers setting contents)

1F7H(ST)

 

 

 

Status information

 

 

 

 

 

 

 

 

 

1F6H(DH)

×

×

×

 

DV

 

xx

 

 

 

 

 

 

 

 

1F5H(CH)

 

 

 

 

xx

 

1F4H(CL)

 

 

 

 

xx

 

1F3H(SN)

 

 

 

 

xx

 

1F2H(SC)

 

 

 

 

xx

 

1F1H(ER)

 

 

 

Error information

 

 

 

 

 

 

 

 

 

(34)SECURITY SET PASSWORD (F1h)

This command enables a user password or master password to be set.

The host transfers the 512-byte data shown in Table 1.2 to the device. The device determines the operation of the lock function according to the specifications of the Identifier bit and Security level bit in the transferred data. (Table 1.3)

Issuing this command in LOCKED MODE or FROZEN MODE returns the Aborted Command error.

C141-E112-01EN

5 - 61

Page 128
Image 128
Fujitsu MPG3XXXAH manual Read Dma, Write Long, Security Disable Password, Read Long, Write Multiple, Security Freeze Lock