Figure 3.17 Jumper setting of Cable Select

2 4 6 8

1 3 5 7 9

CSEL connected to the interface cable selection can be done by the special interface cable.

Figure 3.17 Jumper setting of Cable Select

Figures 3.18 and 3.19 show examples of cable selection using unique interface cables.

By connecting the CSEL of the master device to the CSEL Line (conductor) of the cable and connecting it to ground further, the CSEL is set to low level. The device is identified as a master device. At this time, the CSEL of the slave device does not have a conductor. Thus, since the slave device is not connected to the CSEL conductor, the CSEL is set to high level. The device is identified as a slave device.

GND Figure 3.18 Example (1) of Cable Select

Host system

CSEL conductor

Master device

Open

Slave device

Figure 3.18 Example (1) of Cable Select

CSEL conductor

GND

Open

Host system

Slave device

Master device

Figure 3.19 Example (2) of Cable Select