Normally, room status information is managed in the PMS. Whatever the room status may be, the NEAX operates according to the direction provided from the PMS. The NEAX processes calls within the range shown in Figure A-1If the room status information provided from the PMS does not coincide with the status currently stored by the NEAX, a status closest to the room’s status defined in the NEAX will be designated.

 

Vacant

 

 

 

C/IC

C/I

RC(NEW)

 

 

 

 

 

 

C/O

Stay

MDS

 

C/O

 

 

 

Stay - Cleaning

STC

RDC

RC(NEW)

MDE

STC RDC

 

 

MDS

 

C/O

Departure Day

Departure Day - Cleaning

 

RC(OLD) C/O

C/OC

MDE

 

 

Out

STC

 

Out of Order

 

 

 

MDI

 

 

 

 

STC

MDS

 

STC

 

 

MDE

 

 

 

Cleaning

 

Key

 

 

 

C/I

Check In

 

 

 

MDE

 

C/O

Check Out

 

MDE

Maid Ended Cleaning

 

 

 

 

 

 

MDI

Maid Ended Inspection

 

Inspection

 

MDS

Maid Started Cleaning

 

 

RDC

Room Data Change

 

MDI

 

STC

Status Change

 

 

C/IC

Check In Cancel

 

 

 

C/OC

Check Out Cancel

 

 

 

RC

Room Change

Figure A-1 Room Status in the NEAX

The room status information in the NEAX is processed as a validity check for maid status.

NDA-30115 Revision 1.0

Page A-1

Image 101
Contents NEC America, Inc Property Management SystemLiability Disclaimer Table of Contents NDA-30115 Revision Contents Contents List of Figures FIGURESProperty Management System Communication Interface Tables Title Chapter Overview This Page Left Blank Chapter Architecture Line Control CharacteristicsAsynchronous Transmission ‘1’ ‘!’ 05H Transmission ProtocolMessage Count Range Block Check Code Range 02H ‘1’ ‘!’ ‘L’ 03HTransmission Sequence Sequence From the Neax to the PMSFrom the PMS to the Neax Sender Timer TimersCabling Considerations Receiver Timer Bisynchronous BSC TransmissionEbcdic STX SYNETX ACK0Protocol TransmissionNDA-30115 Revision STX B Neutral a ACK0 NAK ENQ Waiting for ACK lastReceived Waiting for NAK ACK0/1 ETX, CRC25 sec EOT Waiting for EOT a Neutral a ENQ D Waiting for NAK EOT aTimer Values Timers Retransmission Counts CountersST2 ST1 Pin No Signal Cable 20 ER 24 ST1Cabling Considerations Message Descriptions Data Link MaintenanceNDA-30115 Revision NDA-30115 Revision Maid Status Check In/Check Out Model Message Waiting Lamp ControlRestriction Control Check In/Check Out Model Room Move/Swap/Copy Model Wake Up/Group AnnouncementExtension Report Room Data ChangeRoom Recovery Model Direct Data Entry Model Extension Connection This Page Left Blank Message Formats Data Link Maintenance Multiple Function Codes use this message. See below 02H ‘1’ ‘!’ ‘L’ ‘7’ ‘0’ ‘0’ ‘7’ Blank 03H02H ‘1’ ‘!’ ‘L’ ‘1’ ‘7’ Extension Maid 03H CleaningLEN Guest Room02H ‘1’ ‘!’ ‘L’ ‘5’ ‘1’ ‘2’ ‘3’ Extension Maid Room Answer Room Status Cleaning 03H02H ‘1’ ‘!’ ‘L’ ‘5’ ‘1’ ‘2’ ‘0’ Extension Request02H ‘1’ ‘!’ ‘L’ ‘5’ ‘2’ ‘2’ ‘3’ Extension Maid Administration02H ‘1’ ‘!’ ‘L’ ‘3’ ‘1’ ‘1’ Extension 03H MWL Control02H ‘1’ ‘!’ ‘L’ ‘5’ ‘3’ ‘1’ ‘5’ ‘1’ Extension Status MWL StatusOption VMCBlank 03H 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘5’ ‘1’ ‘4’ Extension Code02H ‘1’ ‘!’ ‘L’ ‘1’ ‘6’ ‘1’ ‘1’ Extension 03H CheckCheck Out Message Report Check Out02H ‘1’ ‘!’ ‘L’ ‘1’ ‘6’ ‘1’ ‘1’ ‘2’ Extension 03H VIP Language Stay Display Name 03H 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘6’ ‘3’ ‘4’ ‘B’ Extension Group ID02H ‘1’ ‘!’ ‘L’ ‘1’ ‘6’ ‘1’ ‘1’ ‘C’ Extension 03H Check Out Outgoing Call ReportCheck Out Message Waiting Report 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘6’ ‘1’ ‘3’ ‘D’ Extension StatusLanguage Display Name Data a Data B 03H Cleaning Status KeyNDA-30115 Revision 02H ‘1’ ‘!’ ‘L’ ‘5’ ‘6’ ‘1’ ‘4’ ‘2’ Extension Room Status Cleaning Status Key 03HCheck Out Cancellation Check CancellationRoom Status Cleaning Key 03H 02H ‘1’ ‘!’ ‘L’ ‘5’ ‘6’ ‘1’ ‘1’ ‘4’ Extension 03HRoom Change Key New Extension Room Status Cleaning Status 03H02H ‘1’ ‘!’ ‘L’ ‘5’ ‘6’ ‘1’ ‘1’ ‘7’ Extension 03H Provisional Check02H ‘1’ ‘!’ ‘L’ ‘5’ ‘6’ ‘1’ ‘5’ ‘9’ Extension Status Provisional Check Out02H ‘1’ ‘!’ ‘L’ ‘5’ ‘6’ ‘1’ ‘1’ ‘8’ Extension 03H Source 03H Wake Up Setting Neax02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘6’ ‘1’ Extension Time 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘6’ ‘2’ Extension Blank Wake Up Cancellation NeaxResult 03H Wake Up Execution Result02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘6’ ‘3’ Extension Time 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘6’ ‘4’ Extension Time Wake Up Setting PMS02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘6’ ‘5’ Extension Blank Wake Up Cancellation PMSSource Type 03H Group Announcement Setting Neax02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘7’ ‘6’ Group ID Time 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘6’ ‘7’ Group ID Blank Group Announcement Cancellation NeaxTime Result Type 03H Group Announcement Execution Result02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘2’ ‘3’ ‘8’ Extension Group ID 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘7’ ‘9’ Group ID Time Group Announcement Setting PMS02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘6’ ‘A’ Group ID Blank Group Announcement Cancellation PMS35 Room Move/Swap/Copy Message fields are02H ‘1’ ‘!’ ‘L’ ‘2’ ‘1’ ‘1’ ‘3’ ‘1’ Extension Language Room Data Change02H ‘1’ ‘!’ ‘L’ ‘2’ ‘1’ ‘1’ ‘7’ Extension Group ID 03H Group FormationReservation Cancellation Group CancellationReservation Setting 41 Guest Name Change Guest Name ChangeNDA-30115 Revision 02H ‘1’ ‘!’ ‘L’ ‘6’ ‘1’ ‘1’ ‘3’ ‘3’ Extension Room Status Cleaning Status 03HRoom Status Change 02H ‘1’ ‘!’ ‘L’ ‘6’ ‘1’ ‘1’ ‘2’ ‘4’ Extension Key 03H Room Key Status ChangeExtension Delete Report 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘7’ ‘1’ ‘3’ ‘E’ Extension Blank 03HClass 03H Extension Assignment Report02H ‘1’ ‘!’ ‘L’ ‘1’ ‘7’ ‘1’ ‘3’ ‘F’ Extension Def Room Recovery Model Status Code Blank 03H Room Image Set02H ‘1’ ‘!’ ‘L’ ‘1’ ‘7’ ‘2’ ‘8’ Extension Vacancy 48 Room Image Set 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘7’ ‘2’ ‘3’ Extension Vacancy StatusVIP 49 Room Image Set 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘7’ ‘3’ ‘8’ Extension VacancyVIP 50 Room Data Report Room Data ReportNDA-30115 Revision Guest Room Secretary Telephone Connecting Room02H ‘1’ ‘!’ ‘L’ ‘5’ ‘7’ ‘1’ ‘7’ ‘3’ Boss Secty 03H 02H ‘1’ ‘!’ ‘L’ ‘5’ ‘7’ ‘1’ ‘7’ ‘4’ Master Secondary 03H02H ‘1’ ‘!’ ‘L’ ‘5’ ‘7’ ‘1’ ‘5’ ‘5’ Extension Status Message Status Report02H ‘1’ ‘!’ ‘L’ ‘5’ ‘7’ ‘1’ ‘6’ ‘6’ Extension Time Wake Up02H ‘1’ ‘!’ ‘L’ ‘5’ ‘9’ ‘4’ ‘7’ ‘1’ Extension Numeric Input Direct Data EntryDirect Data Entry Answer 02H ‘1’ ‘!’ ‘L’ ‘5’ ‘9’ ‘1’ ‘7’ Extension57 Guest Room Secretary Telephone 02H ‘1’ ‘!’ ‘L’ ‘6’ ‘2’ ‘1’ ‘7’ Boss Secty 03HConnecting Room Cancel Connecting Room Set02H ‘1’ ‘!’ ‘L’ ‘6’ ‘2’ ‘1’ ‘7’ ‘3’ Master Secondary 03H 02H ‘1’ ‘!’ ‘L’ ‘6’ ‘2’ ‘1’ ‘1’ ‘4’ Master 03HThis Page Left Blank Chapter References This Page Left Blank BCC Chapter GlossaryGlossary Property Management System Communication Interface Appendix a Room Status Dial Steps for Maid Status Updating Room Status Information in the NeaxClearing Room Data Status of Check Out Room Status and Cleaning StatusRoom Data Setting and Clearing in the Neax A-4 NDA-30115 Revision Normal Text Appendix B PMS Line Failure PrintoutsAbnormal Port Abnormal EventsPKG not Ready Line SUP. TimeoutDR OFF/TX not RDY Sinq STOP/S-120Figure B-6 I/O Port Status FC of message Message Data Current Time Transmission FailureB-6 NDA-30115 Revision Data Link Maintenance Appendix C Feature CodesC-2 NDA-30115 Revision Neax ALL Appendix D Function CodesPMS ALL PMS/NEAX ALLCheck Out Cancellation Check In CancellationRoom Image Set 1 Recovery Request Room Image Set 1 Recovery AnswerRoom Image Set 3 Recovery Answer Room Image Set 3 Recovery RequestRecovery Room Data Report Recovery Secretary TelephoneConnecting Room Cancel Connecting Room SetDirect Data Entry Positive Answer Guest Room Secretary Telephone