NEC NDA-30115-001 manual Check Out, 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘6’ ‘1’ ‘1’ ‘2’ Extension 03H

Page 52

Message Formats

Property Management System - Communication Interface

Check Out

0

1

2

3

4

6

8

9

15

16

02H

‘1’

‘!’

‘L’

‘1’ ‘6’

‘1’ ‘1’

‘2’ Extension 03H

xx

STX SA UA EI

FTC

MSC FC

6

ETX BCC

Figure 4-11 Check Out

The only message field is the extension number who is being checked out. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters. The Room Status is set to “Out” and Room Cut-Off is set.

Check Out

Message Report

0

1

2

3

4

6

8

9

15

16

02H

‘1’

‘!’

‘L’

‘1’ ‘6’

‘1’ ‘1’

**

Extension 03H

xx

STX SA UA EI

FTC

MSC FC

6

ETX BCC

** Multiple Function Codes use this message. See below.

Figure 4-12 Check Out Message Waiting Lamp Report

Message fields are:

FC-- There are two functions: (FTC-FC)

16-5 -- Check Out Message Waiting Lamp Off Report

16-6 -- Check Out Message Waiting Lamp On Report

Extension -- Extension number. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters.

Page 42

NDA-30115 Revision 1.0

Image 52
Contents Property Management System NEC America, IncLiability Disclaimer Table of Contents NDA-30115 Revision Contents Contents List of Figures FIGURESProperty Management System Communication Interface Tables Title Chapter Overview This Page Left Blank Chapter Architecture Asynchronous Transmission CharacteristicsLine Control Transmission Protocol ‘1’ ‘!’ 05H02H ‘1’ ‘!’ ‘L’ 03H Message Count Range Block Check Code RangeTransmission Sequence From the Neax to the PMS SequenceFrom the PMS to the Neax Timers Sender TimerCabling Considerations Receiver Timer Bisynchronous BSC TransmissionEbcdic SYN STXETX ACK0Transmission ProtocolNDA-30115 Revision Neutral a ACK0 NAK ENQ Waiting for ACK last STX BReceived Waiting for NAK ACK0/1 ETX, CRCNeutral a ENQ D Waiting for NAK EOT a 25 sec EOT Waiting for EOT aTimers Retransmission Counts Counters Timer ValuesCabling Considerations Pin No Signal Cable 20 ER 24 ST1ST2 ST1 Data Link Maintenance Message DescriptionsNDA-30115 Revision NDA-30115 Revision Maid Status Restriction Control Message Waiting Lamp ControlCheck In/Check Out Model Check In/Check Out Model Wake Up/Group Announcement Room Move/Swap/Copy ModelRoom Data Change Extension ReportRoom Recovery Model Direct Data Entry Model Extension Connection This Page Left Blank Message Formats Data Link Maintenance 02H ‘1’ ‘!’ ‘L’ ‘7’ ‘0’ ‘0’ ‘7’ Blank 03H Multiple Function Codes use this message. See belowCleaning 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘7’ Extension Maid 03H02H ‘1’ ‘!’ ‘L’ ‘5’ ‘1’ ‘2’ ‘3’ Extension Maid Guest RoomLEN Room Status Cleaning 03H Room Answer02H ‘1’ ‘!’ ‘L’ ‘5’ ‘1’ ‘2’ ‘0’ Extension RequestAdministration 02H ‘1’ ‘!’ ‘L’ ‘5’ ‘2’ ‘2’ ‘3’ Extension MaidMWL Control 02H ‘1’ ‘!’ ‘L’ ‘3’ ‘1’ ‘1’ Extension 03H MWL Status 02H ‘1’ ‘!’ ‘L’ ‘5’ ‘3’ ‘1’ ‘5’ ‘1’ Extension Status Option VMC02H ‘1’ ‘!’ ‘L’ ‘1’ ‘5’ ‘1’ ‘4’ Extension Code Blank 03HCheck 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘6’ ‘1’ ‘1’ Extension 03H02H ‘1’ ‘!’ ‘L’ ‘1’ ‘6’ ‘1’ ‘1’ ‘2’ Extension 03H Check OutCheck Out Message Report VIP 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘6’ ‘3’ ‘4’ ‘B’ Extension Group ID Language Stay Display Name 03HCheck Out Outgoing Call Report 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘6’ ‘1’ ‘1’ ‘C’ Extension 03HCheck Out Message Waiting Report 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘6’ ‘1’ ‘3’ ‘D’ Extension StatusCleaning Status Key Language Display Name Data a Data B 03HNDA-30115 Revision Cleaning Status Key 03H 02H ‘1’ ‘!’ ‘L’ ‘5’ ‘6’ ‘1’ ‘4’ ‘2’ Extension Room StatusCheck Cancellation Check Out CancellationRoom Status Cleaning Key 03H 02H ‘1’ ‘!’ ‘L’ ‘5’ ‘6’ ‘1’ ‘1’ ‘4’ Extension 03HKey New Extension Room Status Cleaning Status 03H Room ChangeProvisional Check 02H ‘1’ ‘!’ ‘L’ ‘5’ ‘6’ ‘1’ ‘1’ ‘7’ Extension 03H02H ‘1’ ‘!’ ‘L’ ‘5’ ‘6’ ‘1’ ‘1’ ‘8’ Extension 03H Provisional Check Out02H ‘1’ ‘!’ ‘L’ ‘5’ ‘6’ ‘1’ ‘5’ ‘9’ Extension Status 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘6’ ‘1’ Extension Time Wake Up Setting NeaxSource 03H Wake Up Cancellation Neax 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘6’ ‘2’ Extension Blank02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘6’ ‘3’ Extension Time Wake Up Execution ResultResult 03H Wake Up Setting PMS 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘6’ ‘4’ Extension TimeWake Up Cancellation PMS 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘6’ ‘5’ Extension Blank02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘7’ ‘6’ Group ID Time Group Announcement Setting NeaxSource Type 03H Group Announcement Cancellation Neax 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘6’ ‘7’ Group ID Blank02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘2’ ‘3’ ‘8’ Extension Group ID Group Announcement Execution ResultTime Result Type 03H Group Announcement Setting PMS 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘7’ ‘9’ Group ID TimeGroup Announcement Cancellation PMS 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘9’ ‘1’ ‘6’ ‘A’ Group ID BlankMessage fields are 35 Room Move/Swap/CopyRoom Data Change 02H ‘1’ ‘!’ ‘L’ ‘2’ ‘1’ ‘1’ ‘3’ ‘1’ Extension LanguageGroup Formation 02H ‘1’ ‘!’ ‘L’ ‘2’ ‘1’ ‘1’ ‘7’ Extension Group ID 03HReservation Setting Group CancellationReservation Cancellation Guest Name Change 41 Guest Name ChangeNDA-30115 Revision Room Status Change Cleaning Status 03H02H ‘1’ ‘!’ ‘L’ ‘6’ ‘1’ ‘1’ ‘3’ ‘3’ Extension Room Status Room Key Status Change 02H ‘1’ ‘!’ ‘L’ ‘6’ ‘1’ ‘1’ ‘2’ ‘4’ Extension Key 03HExtension Delete Report 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘7’ ‘1’ ‘3’ ‘E’ Extension Blank 03H02H ‘1’ ‘!’ ‘L’ ‘1’ ‘7’ ‘1’ ‘3’ ‘F’ Extension Def Extension Assignment ReportClass 03H Room Recovery Model 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘7’ ‘2’ ‘8’ Extension Vacancy Room Image SetStatus Code Blank 03H 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘7’ ‘2’ ‘3’ Extension Vacancy Status 48 Room Image SetVIP 02H ‘1’ ‘!’ ‘L’ ‘1’ ‘7’ ‘3’ ‘8’ Extension Vacancy 49 Room Image SetVIP Room Data Report 50 Room Data ReportNDA-30115 Revision Connecting Room Guest Room Secretary Telephone02H ‘1’ ‘!’ ‘L’ ‘5’ ‘7’ ‘1’ ‘7’ ‘3’ Boss Secty 03H 02H ‘1’ ‘!’ ‘L’ ‘5’ ‘7’ ‘1’ ‘7’ ‘4’ Master Secondary 03HMessage Status Report 02H ‘1’ ‘!’ ‘L’ ‘5’ ‘7’ ‘1’ ‘5’ ‘5’ Extension StatusWake Up 02H ‘1’ ‘!’ ‘L’ ‘5’ ‘7’ ‘1’ ‘6’ ‘6’ Extension TimeDirect Data Entry 02H ‘1’ ‘!’ ‘L’ ‘5’ ‘9’ ‘4’ ‘7’ ‘1’ Extension Numeric InputDirect Data Entry Answer 02H ‘1’ ‘!’ ‘L’ ‘5’ ‘9’ ‘1’ ‘7’ Extension02H ‘1’ ‘!’ ‘L’ ‘6’ ‘2’ ‘1’ ‘7’ Boss Secty 03H 57 Guest Room Secretary TelephoneConnecting Room Set Connecting Room Cancel02H ‘1’ ‘!’ ‘L’ ‘6’ ‘2’ ‘1’ ‘7’ ‘3’ Master Secondary 03H 02H ‘1’ ‘!’ ‘L’ ‘6’ ‘2’ ‘1’ ‘1’ ‘4’ Master 03HThis Page Left Blank Chapter References This Page Left Blank Chapter Glossary BCCGlossary Property Management System Communication Interface Appendix a Room Status Clearing Room Data Updating Room Status Information in the NeaxDial Steps for Maid Status Room Data Setting and Clearing in the Neax Room Status and Cleaning StatusStatus of Check Out A-4 NDA-30115 Revision Appendix B PMS Line Failure Printouts Normal TextAbnormal Events Abnormal PortLine SUP. Timeout PKG not ReadyDR OFF/TX not RDY Sinq STOP/S-120Figure B-6 I/O Port Status Transmission Failure FC of message Message Data Current TimeB-6 NDA-30115 Revision Appendix C Feature Codes Data Link MaintenanceC-2 NDA-30115 Revision Appendix D Function Codes Neax ALLPMS ALL PMS/NEAX ALLCheck In Cancellation Check Out CancellationRoom Image Set 1 Recovery Request Room Image Set 1 Recovery AnswerRoom Image Set 3 Recovery Request Room Image Set 3 Recovery AnswerRecovery Room Data Report Recovery Secretary TelephoneConnecting Room Set Connecting Room CancelDirect Data Entry Positive Answer Guest Room Secretary Telephone